M800/M80/E80/C80 Series Alarm/Parameter Manual
1 Operation Errors (M)
12
IB-1501279-H
Details
Restart switch has been turned ON and manual mode has been selected before the restart search is complet-
ed.
Remedy
Search the block to restart.
Turn the restart switch OFF.
Details
The cycle start button was pressed during program check or in program check mode.
Remedy
Press the reset button to cancel the program check mode.
Details
The cycle start button was pressed during buffer correction.
Remedy
Press the cycle start button after the buffer correction is completed.
Details
The cycle start button was pressed during resetting or tape rewinding.
Remedy
When rewinding the tape, wait for the winding to end, or press the reset button to stop the winding, and
then press the cycle start button.
During resetting, wait for the resetting to end, and then press the automatic start button.
Details
The playback switch was turned ON during editing.
Remedy
Cancel the editing by pressing the input or previous screen key before turning ON the playback switch.
Details
The turning angle at the block joint exceeded the limit during normal line control.
In normal line control type I:
The parameter "#1523 C_feed" (Normal line control axis turning speed) has not been set.
In normal line control type II:
When turning in the inside of the arc, the set value for the parameter "#8041 C-rot. R" is larger than the arc
radius.
Remedy
Correct the program.
Correct the parameter "#1523 C_feed" (Normal line control axis turning speed) setting.
Correct the parameter "#8041 C-rot. R" setting.
Details
Any of the following conditions are occurring.
a) There is no block to run backward
b) Eight blocks without a travel command continued
Remedy
Execute forward run to clear the alarm.
Reset to clear the alarm.
M01
Restart switch ON
0111
M01
Program check mode
0112
M01
Cycle st. in buffer correct
0113
M01
In reset process
0115
M01
Playback not possible
0117
M01
Turn stop in normal line cntrl
0118
M01
Reverse run impossible
0119
Содержание C80 Series
Страница 1: ......
Страница 7: ......
Страница 11: ......
Страница 13: ......
Страница 15: ......
Страница 18: ...1 IB 1501279 H Alarm ...
Страница 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Страница 20: ...1 3 IB 1501279 H Operation Errors M ...
Страница 54: ...2 37 IB 1501279 H Stop Codes T ...
Страница 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Страница 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Страница 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Страница 98: ...5 81 IB 1501279 H System Alarms Z ...
Страница 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Страница 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Страница 117: ...M800 M80 E80 C80 Series Alarm Parameter Manual 6 Absolute Position Detection System Alarms Z7 100 IB 1501279 H ...
Страница 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Страница 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Страница 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Страница 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Страница 136: ...11 119 IB 1501279 H Network Service Errors N ...
Страница 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Страница 140: ...12 123 IB 1501279 H Program Errors P ...
Страница 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Страница 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Страница 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Страница 216: ...199 IB 1501279 H Parameter ...
Страница 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Страница 218: ...15 201 IB 1501279 H User Parameters ...
Страница 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Страница 360: ...16 343 IB 1501279 H Machine Parameters ...
Страница 748: ......