M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
635
IB-1501279-H
Set the compensation data No. at the farthest end on the positive side.
(Note) When the axis moves in negative direction with two-way pitch error compensation enabled, set com-
pensation data No. of which locates on the nearest point to positive side. The compensation point should
be set with even number.
---Setting range---
4101 to 5124
Set the scale factor for the compensation amount.
---Setting range---
0 to 99
Set the interval to divide the basic axis.
Each compensation data will be the compensation amount for each of these intervals.
---Setting range---
0.001 to 9999.999 (mm)
Select whether to enable two-way pitch error compensation.
0: Disable
1: Enable
When two-way pitch error compensation is enabled, set the compensation amount of the reference position
when the axis moves to the position from the opposite direction of the zero point return.
---Setting range---
-32768 to 32767
(Note) The actual compensation amount will be the value obtained by multiplying the setting value with the
compensation scale.
Set the compensation amount for each axis.
---Setting range---
-32768 to 32767
(Note) The actual compensation amount will be the value obtained by multiplying the setting value with the
compensation scale.
#4005
pdvno
Division point number at the most positive side <n-th
axis>
#4006
sc
Compensation scale factor <n-th axis>
#4007
spcdv
Division interval <n-th axis>
#4008
twopc
Two-way pitch error compensation <n-th axis>
#4009
refcmp
Reference position compensation amount <n-th axis>
#4101-5999
Содержание C80 Series
Страница 1: ......
Страница 7: ......
Страница 11: ......
Страница 13: ......
Страница 15: ......
Страница 18: ...1 IB 1501279 H Alarm ...
Страница 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Страница 20: ...1 3 IB 1501279 H Operation Errors M ...
Страница 54: ...2 37 IB 1501279 H Stop Codes T ...
Страница 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Страница 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Страница 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Страница 98: ...5 81 IB 1501279 H System Alarms Z ...
Страница 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Страница 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Страница 117: ...M800 M80 E80 C80 Series Alarm Parameter Manual 6 Absolute Position Detection System Alarms Z7 100 IB 1501279 H ...
Страница 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Страница 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Страница 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Страница 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Страница 136: ...11 119 IB 1501279 H Network Service Errors N ...
Страница 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Страница 140: ...12 123 IB 1501279 H Program Errors P ...
Страница 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Страница 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Страница 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Страница 216: ...199 IB 1501279 H Parameter ...
Страница 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Страница 218: ...15 201 IB 1501279 H User Parameters ...
Страница 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Страница 360: ...16 343 IB 1501279 H Machine Parameters ...
Страница 748: ......