M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
262
IB-1501279-H
[M8]
Set the comment (date, time, etc.) display position (nth word from left) of the list displayed when the ftp com-
mand "dir" is executed.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---
0 to 100
0: Default value
[C80]
Not used.
[M8]
Set the number of words to be displayed as a comment.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---
0 to 100
0: Default value
[C80]
Not used.
[M8]
Set whether to display the total number of characters registered in the machining programs of host1 when
displaying the file list.
If there are many files in the directory to be referred to, the list can be updated quickly by setting "1".
0: Display
1: Not display
[C80]
Not used.
[M8]
Set the host computer name.
This parameter allows the NC to easily recognize the host computer on the network. Set the host computer's
name (name registered in C:\windows\hosts) or the IP address.
<Setting example>
For host name: mspc160
For IP address: 150.40.0.111
(Note) Set the host computer's TCP/IP address if communication is not carried out correctly.
---Setting range---
15 characters (alphanumeric) or less
[C80]
Not used.
#9739
Host 2 Wrd pos: cmnt
#9740
Host 2 Wrd num: cmnt
#9741
Host 2 no total siz
#9751
Host3 host name
Содержание C80 Series
Страница 1: ......
Страница 7: ......
Страница 11: ......
Страница 13: ......
Страница 15: ......
Страница 18: ...1 IB 1501279 H Alarm ...
Страница 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Страница 20: ...1 3 IB 1501279 H Operation Errors M ...
Страница 54: ...2 37 IB 1501279 H Stop Codes T ...
Страница 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Страница 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Страница 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Страница 98: ...5 81 IB 1501279 H System Alarms Z ...
Страница 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Страница 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Страница 117: ...M800 M80 E80 C80 Series Alarm Parameter Manual 6 Absolute Position Detection System Alarms Z7 100 IB 1501279 H ...
Страница 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Страница 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Страница 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Страница 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Страница 136: ...11 119 IB 1501279 H Network Service Errors N ...
Страница 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Страница 140: ...12 123 IB 1501279 H Program Errors P ...
Страница 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Страница 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Страница 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Страница 216: ...199 IB 1501279 H Parameter ...
Страница 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Страница 218: ...15 201 IB 1501279 H User Parameters ...
Страница 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Страница 360: ...16 343 IB 1501279 H Machine Parameters ...
Страница 748: ......