M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
427
IB-1501279-H
bit0: Spindle speed clamp check
Select whether to check the spindle speed clamp under the constant surface speed control.
0: Check the spindle speed clamp.
1: Not check the spindle speed clamp.
(Note) This parameter is enabled when the parameter "#1146 Sclamp" is set to "1".
bit1: Spindle control selected in response to Z83 (NC started during SP rotation)
Select whether to force-stop the spindle when the alarm (Z83 0001) occurs.
0: Not force-stop the spindle
1: Force-stop the spindle
bit3: M code output during multi-system simultaneous simulation (Check type II)
[M8]
Select whether to enable a miscellaneous function code output during execution of multi-part system simul-
taneous simulation (Check type II).
0: Not output a miscellaneous function
1: Output a miscellaneous function
(Note) When the output is enabled, the miscellaneous codes specified in #1406 S_mode(SMLK), #1407 T_-
mode(SMLK), #1408 M2_mode(SMLK) and #1451 M[M031-000](SMLK) to #1466 M[M511-480](SMLK) can
be output.
M code output specification is determined by #1405 M_mode(SMLK).
[C80]
Not used.
bit6: Automatic operation handle interruption during inclined surface machining
Select whether to enable the automatic operation handle interruption function during inclined surface machin-
ing.
0: Disable
1: Enable
bit0: Multi-part system program management
Select whether to use multi-part system program management.
0: Not use
1: Use
(Note) When this parameter's value is changed, the power must be turned OFF and ON, and the system for-
matted. Two or more part systems from [1] to [4] need to be set to "1" in "#1001 SYS_ON". Otherwise this
parameter will be disabled even though set to "1".
bit1: Program search type switch
Select how to search a program to operate.
0: Operation search is performed in the selected part system.
1: Operation search is performed for all part systems. (The program No. will be common to all part sys-
tems.)
bit2: Multi-part system program generation and operation
Select whether to perform the following processes for all the part systems or for each part system separately
in multi-part system program management: newly create, delete or rename the machining programs in NC
memory (including MDI program and machine tool builder macro program) or transfer, compare, merge the
programs between NC memory and other device.
0: Perform these processes for the programs in all the part systems. If no subprogram contents are found
by the subprogram call during automatic operation, the program will be searched for and executed from
$1.
1: Perform these processes for the programs in the selected part system.
(PR)
#1284
ext20
(PR)
#1285
ext21
Содержание C80 Series
Страница 1: ......
Страница 7: ......
Страница 11: ......
Страница 13: ......
Страница 15: ......
Страница 18: ...1 IB 1501279 H Alarm ...
Страница 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Страница 20: ...1 3 IB 1501279 H Operation Errors M ...
Страница 54: ...2 37 IB 1501279 H Stop Codes T ...
Страница 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Страница 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Страница 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Страница 98: ...5 81 IB 1501279 H System Alarms Z ...
Страница 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Страница 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Страница 117: ...M800 M80 E80 C80 Series Alarm Parameter Manual 6 Absolute Position Detection System Alarms Z7 100 IB 1501279 H ...
Страница 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Страница 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Страница 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Страница 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Страница 136: ...11 119 IB 1501279 H Network Service Errors N ...
Страница 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Страница 140: ...12 123 IB 1501279 H Program Errors P ...
Страница 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Страница 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Страница 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Страница 216: ...199 IB 1501279 H Parameter ...
Страница 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Страница 218: ...15 201 IB 1501279 H User Parameters ...
Страница 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Страница 360: ...16 343 IB 1501279 H Machine Parameters ...
Страница 748: ......