M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
436
IB-1501279-H
[M8]
Specify a period of time during which the control does not detect a Fieldbus communication error of the Field-
bus expansion card mounted in the slot EXT3 (or EXT1 for M80/M800S/E80), after startup of the NC is com-
pleted.
Set this in 0.1-second increments.
(Note 1) This parameter is enabled for all the communication expansion cards except CC-Link expansion
card.
(Note 2) PROFIBUS-DP communication expansion card refers to this parameter, whichever slot (EXT3 or
EXT4 (or EXT1 or EXT2 for M80/M800S/E80)) the card is mounted in. It does not refer to the pa-
rameter #1490.
---Setting range---
0 to 60000 (0.1s)
Select whether to restrain the lost motion compensation in handle mode.
0: Restrain
1: Not restrain
Select the start cycle of PLC main processing program.
When wait time until the next start cycle from 1 scan end is long, the wait time can be shortened by adjusting
the start cycle.
-1: Low-speed mode (2 fold)
0: Standard mode
1: High-speed mode 1 (1/2 fold)
2: High-speed mode 2 (1/4 fold)
(Note 1) When the high-speed mode is selected, the fine segment processing performance may degrade due
to the increased processing load of the system.
(Note 2) When the high-speed mode 2 is selected, the scan time should be 1/4 or less of the base interruption
cycle as a standard. If the standard is exceeded, the update of all the DI/DOs in refresh cycle may not be
able to be performed.
(Note 3) If the number of RIO stations connected is large, the update of all the RIO in refresh cycle may not
be able to be performed. Make the setting according to the number of stations per RIO channel.
Select the acceleration/deceleration mode in jog feed, incremental feed and manual reference position return
(when rapid traverse signal OFF).
0: Acceleration/Deceleration for rapid traverse
1: Acceleration/Deceleration for cutting feed
Select whether the #400-level variables are used as machine tool builder macro variables or as common vari-
ables.
0: #400 to #449 are not available; #450 to #499 are used as machine tool builder macro variables.
1: #400 to #499 are used as common variables
(Note) 700 sets or more of common variables are required for using #400 to #499 as common variables. If
this parameter is set to "1" while the number of common variables is set to less than 700, this parameter
setting will be regarded as "0".
Select the condition to start/stop saving reverse run data.
0: Start when the reverse run control mode signal is turned ON. Stop when turned OFF.
1: Start when the reverse run control mode signal is ON and macro interrupt is valid (M96/ION).
Stop when the reverse run control mode signal is OFF or macro interruption is finished (M97/IOF) (com-
patible with M500M).
(PR)
#1332
F-bus init delay
Fieldbus communication error invalid time
#1333
LMC restrain
Lost motion compensation restraint in handle mode
(PR)
#1334
DI/DO refresh cycl
DI/DO refresh cycle
#1335
man_smg
Manual feed acceleration/deceleration selection
(PR)
#1336
#400_Valtype
#400 address variable type
(PR)
#1338
rev data save trg
Trigger switching to save arbitrary reverse run data
Содержание C80 Series
Страница 1: ......
Страница 7: ......
Страница 11: ......
Страница 13: ......
Страница 15: ......
Страница 18: ...1 IB 1501279 H Alarm ...
Страница 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Страница 20: ...1 3 IB 1501279 H Operation Errors M ...
Страница 54: ...2 37 IB 1501279 H Stop Codes T ...
Страница 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Страница 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Страница 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Страница 98: ...5 81 IB 1501279 H System Alarms Z ...
Страница 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Страница 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Страница 117: ...M800 M80 E80 C80 Series Alarm Parameter Manual 6 Absolute Position Detection System Alarms Z7 100 IB 1501279 H ...
Страница 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Страница 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Страница 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Страница 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Страница 136: ...11 119 IB 1501279 H Network Service Errors N ...
Страница 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Страница 140: ...12 123 IB 1501279 H Program Errors P ...
Страница 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Страница 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Страница 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Страница 216: ...199 IB 1501279 H Parameter ...
Страница 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Страница 218: ...15 201 IB 1501279 H User Parameters ...
Страница 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Страница 360: ...16 343 IB 1501279 H Machine Parameters ...
Страница 748: ......