M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
284
IB-1501279-H
Set the compensation coefficient to further reduce or increase the roundness at the corner during the high-
accuracy control mode.
Coefficient = 100 - setting value
(Note) This is valid when "#8021 COMP CHANGE" is set to "1".
Reference to "#8020 Corner decreasing speed "for theoretical corner roundness amount, corner decreasing
speed, theoretical 90 degree dull amount, 90 degree corner decreasing speed.
---Setting range---
-1000 to 99 (%)
Set the compensation coefficient to further reduce or increase the radius reduction amount at the curve (arc,
involute, spline) during the high-accuracy control mode.
Coefficient = 100 - setting value
(Note) This is valid when "#8021 COMP CHANGE" is set to "1".
For theoretical radius reduction error amount, R5mm arc deceleration speed and R1mm arc deceleration
speed, refer to "#8019 R COMP".
---Setting range---
-1000 to 99 (%)
For M system only.
Specify whether to enable the fine spline function.
0: Disable the fine spline function.
1: Enable the fine spline function.
Spline interpolation will be valid during G61.2 modal regardless of this setting.
Set the angle where the spline interpolation is temporarily canceled.
When the angle made by blocks exceeds this parameter setting value, spline interpolation will be canceled
temporarily. In consideration of the pick feed, set a value a little smaller than the pick feed angle.
---Setting range---
0 to 180 (°)
0: 180 (°)
Set the maximum chord error (tolerance) in a block that includes an inflection point. Set the tolerance appli-
cable when the applicable block is developed to fine segments by CAM. (normally about 10
μ
m)
When "0.000" is set, the applicable block will be linear.
---Setting range---
0.000 to 100.000 (mm)
Set the maximum chord error (tolerance) in a block that includes no inflection point. Set the tolerance appli-
cable when the applicable block is developed to fine segments by CAM. (normally about 10
μ
m)
When "0.000" is set, the applicable block will be linear.
---Setting range---
0.000 to 100.000 (mm)
Set the length of the block subject to fairing.
(Enabled when "#8033 Fairing ON" is set to "1".)
---Setting range---
0 to 100.000 (mm)
#8022
CORNER COMP
#8023
CURVE COMP
#8025
SPLINE ON
#8026
CANCEL ANG. (for M system only)
#8027
Toler-1 (for M system only)
#8028
Toler-2 (for M system only)
#8029
FairingL (for M system only)
Содержание C80 Series
Страница 1: ......
Страница 7: ......
Страница 11: ......
Страница 13: ......
Страница 15: ......
Страница 18: ...1 IB 1501279 H Alarm ...
Страница 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Страница 20: ...1 3 IB 1501279 H Operation Errors M ...
Страница 54: ...2 37 IB 1501279 H Stop Codes T ...
Страница 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Страница 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Страница 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Страница 98: ...5 81 IB 1501279 H System Alarms Z ...
Страница 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Страница 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Страница 117: ...M800 M80 E80 C80 Series Alarm Parameter Manual 6 Absolute Position Detection System Alarms Z7 100 IB 1501279 H ...
Страница 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Страница 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Страница 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Страница 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Страница 136: ...11 119 IB 1501279 H Network Service Errors N ...
Страница 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Страница 140: ...12 123 IB 1501279 H Program Errors P ...
Страница 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Страница 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Страница 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Страница 216: ...199 IB 1501279 H Parameter ...
Страница 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Страница 218: ...15 201 IB 1501279 H User Parameters ...
Страница 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Страница 360: ...16 343 IB 1501279 H Machine Parameters ...
Страница 748: ......