Set the TLM standard length.
TLM standard length is the distance from a tool replacement point (reference position) to the measurement
basic point (surface) which is used to measure the tool length.
(The same value as "#2016 tlml+" will be reflected. When either setting changes, the other will change ac-
cordingly.)
---Setting range---
-99999.999 to 99999.999 (mm)
Select the performance after establishing the reference position in reference position return command.
0: Moves to the reference position.
1: Won't move to the reference position.
[M8]
Set a drawing start position in graphic check of each axis.
Set a distance from actual machine position by an incremental value.
When "0" is set, an actual machine position will be regarded as a start point in graphic check.
---Setting range---
-99999.999 to 99999.999 (mm)
[C80]
Not used.
Set in which direction and how much the tool escapes when the operation is halted during direct command
mode. (Radius value)
The tool does not escape when "0" is set.
---Setting range---
-99999.999 to 99999.999 (mm)
Set the retract amount using the radius value when the Hob retract amount selection signal is OFF.
Retract is carried out in the negative direction if a negative value is set.
---Setting range---
-99999.999 to 99999.999 (mm)
Set the retract amount using the radius value when the Hob retract amount selection signal is ON.
Retract is carried out in the negative direction if a negative value is set.
---Setting range---
-99999.999 to 99999.999 (mm)
Set the retract speed during hobbing.
---Setting range---
1 to 1000000 (mm/min)
Current position display range
Select the display range of the current position.
0: 0 to 359.999 deg
1: -99999.999 to 99999.999 deg
#8215
TLM std length
#8216
Type in G28 return
#8217
Check start point
#8218
Dir cmd retrct amt
#8219
Hob retract amount 1
#8220
Hob retract amount 2
#8221
Hob retract speed
(PR)
#8224
Posn display range
Содержание C80 Series
Страница 1: ......
Страница 7: ......
Страница 11: ......
Страница 13: ......
Страница 15: ......
Страница 18: ...1 IB 1501279 H Alarm ...
Страница 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Страница 20: ...1 3 IB 1501279 H Operation Errors M ...
Страница 54: ...2 37 IB 1501279 H Stop Codes T ...
Страница 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Страница 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Страница 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Страница 98: ...5 81 IB 1501279 H System Alarms Z ...
Страница 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Страница 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Страница 117: ...M800 M80 E80 C80 Series Alarm Parameter Manual 6 Absolute Position Detection System Alarms Z7 100 IB 1501279 H ...
Страница 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Страница 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Страница 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Страница 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Страница 136: ...11 119 IB 1501279 H Network Service Errors N ...
Страница 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Страница 140: ...12 123 IB 1501279 H Program Errors P ...
Страница 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Страница 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Страница 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Страница 216: ...199 IB 1501279 H Parameter ...
Страница 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Страница 218: ...15 201 IB 1501279 H User Parameters ...
Страница 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Страница 360: ...16 343 IB 1501279 H Machine Parameters ...
Страница 748: ......