M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
549
IB-1501279-H
< Spindle synchronization multi-step acceleration/deceleration control parameter >
The acceleration/deceleration control can be set up to eight steps in spindle synchronization control to carry out an optimal
acceleration/deceleration control in accordance with the spindle motor characteristics whose output torque steps down
when exceeding the base rotation speed and further attenuate in output stepdown zone.
For 2nd step or subsequent steps, the specification allows to set the time constant magnification and changeover rotation
speed based on the acceleration/deceleration setting of the 1st step.
Set the value of limit rotation speed or higher as the changeover rotation speed for the step not to be shifted when not car-
rying out a step shift.
Not used. Set to "0".
Set the deceleration rate of the encoder to the spindle when inputting ABZ pulse output encoder feedback to
NC during analog spindle control.
0: 1/1
1: 1/2
2: 1/4
3: 1/8
---Setting range---
0 to 3
#3021
#3022
sgear
Encoder gear ratio
4000
6000
8000
sptc7=9200
sptc6=8200
sptc5=7200
sptc4=6000
sptc3=4800
sptc2=3000
sptc1=1000
0
spt=400
slimit1=10000
1200(=spt * spdiv1 = 400 * 3)
2000(=spt * spdiv2 = 400 * 5)
2800(=spt * spdiv3 = 400 * 7)
4000(=spt * spdiv4 = 400 * 10)
5600(=spt * spdiv5 = 400 * 14)
8000(=spt * spdiv6 = 400 * 20)
11200(=spt * spdiv7 = 400 * 28)
0
2000
3000
4000
1000
10000
2000
Time [ms]
Spindle rotation speed [r/min]
Содержание C80 Series
Страница 1: ......
Страница 7: ......
Страница 11: ......
Страница 13: ......
Страница 15: ......
Страница 18: ...1 IB 1501279 H Alarm ...
Страница 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Страница 20: ...1 3 IB 1501279 H Operation Errors M ...
Страница 54: ...2 37 IB 1501279 H Stop Codes T ...
Страница 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Страница 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Страница 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Страница 98: ...5 81 IB 1501279 H System Alarms Z ...
Страница 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Страница 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Страница 117: ...M800 M80 E80 C80 Series Alarm Parameter Manual 6 Absolute Position Detection System Alarms Z7 100 IB 1501279 H ...
Страница 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Страница 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Страница 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Страница 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Страница 136: ...11 119 IB 1501279 H Network Service Errors N ...
Страница 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Страница 140: ...12 123 IB 1501279 H Program Errors P ...
Страница 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Страница 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Страница 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Страница 216: ...199 IB 1501279 H Parameter ...
Страница 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Страница 218: ...15 201 IB 1501279 H User Parameters ...
Страница 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Страница 360: ...16 343 IB 1501279 H Machine Parameters ...
Страница 748: ......