M800/M80/E80/C80 Series Alarm/Parameter Manual
1 Operation Errors (M)
21
IB-1501279-H
Details
Compensation amount calculation was excessive, so the amount was clamped by +/- 1mm.
Remedy
Review the position deviation and angular deviation values.
Details
You executed cycle start while measurement of rotation center error or workpiece installation error is invalid.
Remedy
Execute cycle start for one part system that is ready for measurement.
Activate memory mode before executing cycle start.
Details
You switched the operation to any mode other than memory during measurement of rotation center error or
workpiece installation error.
Remedy
Switch the operation to memory mode.
Manual interruption, automatic operation handle interruption, MDI interruption, etc. are invalid during error mea-
surement.
Execute cycle start after completion or cancel of the measurement.
Details
Machining surface operation (selection, indexing or cancel) was attempted while the operation is disabled.
Remedy
Cancel the other modes so that the inclined surface machining command (G68.2), tool axis direction con-
trol (G53.1) and the inclined surface machining cancel command (G69) can be issued.
Wait until the axes stop completely (until the smoothing for all axes reaches zero).
Perform operation search for machining programs.
Details
Moving a rotary axis was attempted during manual machining surface indexing, when a manual operation
mode other than handle mode was selected.
Remedy
Change the operation mode to a handle mode before carrying out the manual surface indexing.
Details
The tool length compensation amount for performing the R-Navi indexing type 2 is 0.
Remedy
Set the tool length compensation amount for performing the indexing type 2 to a value other than 0.
Details
Manual feed feature coordinate system was selected while two or more handles were ON.
Remedy
Manual feed on a feature coordinate system is disabled while two or more handles are enabled (*).
Press [Manual coord] and select the machine coordinate system.
Reduce the number of enabled handles (*) to one.
(*) An enabled handle means the handle for which "Nth handle valid" signal (HSnS) is ON.
M01
Rot center err comp excessive
0241
M01
Unable to start measuring err
0245
M01
Invalid op mode in err measure
0246
M01
Machining surface operation disabled
0250
M01
Axs travel n/a in manual index
0251
M01
Tool length compensation amt 0
0252
M01
Feat coord ill w/ multi-handle
0253
Содержание C80 Series
Страница 1: ......
Страница 7: ......
Страница 11: ......
Страница 13: ......
Страница 15: ......
Страница 18: ...1 IB 1501279 H Alarm ...
Страница 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Страница 20: ...1 3 IB 1501279 H Operation Errors M ...
Страница 54: ...2 37 IB 1501279 H Stop Codes T ...
Страница 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Страница 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Страница 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Страница 98: ...5 81 IB 1501279 H System Alarms Z ...
Страница 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Страница 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Страница 117: ...M800 M80 E80 C80 Series Alarm Parameter Manual 6 Absolute Position Detection System Alarms Z7 100 IB 1501279 H ...
Страница 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Страница 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Страница 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Страница 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Страница 136: ...11 119 IB 1501279 H Network Service Errors N ...
Страница 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Страница 140: ...12 123 IB 1501279 H Program Errors P ...
Страница 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Страница 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Страница 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Страница 216: ...199 IB 1501279 H Parameter ...
Страница 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Страница 218: ...15 201 IB 1501279 H User Parameters ...
Страница 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Страница 360: ...16 343 IB 1501279 H Machine Parameters ...
Страница 748: ......