14 Multi CPU Errors (A) [C80]
187
IB-1501279-H
Details
In the multiple CPU system, the system parameter settings of the host CPU module differ from those of
other CPU modules.
In the multiple CPU system, the system parameter settings are overwritten only to the host CPU module,
and the settings differ from those of other CPU modules.
Remedy
Check the detailed information (parameter information) of the error by executing module diagnostics using
the engineering tool, and correct the system parameter settings corresponding to the displayed number for
the CPU No.2 and later. The settings need to be the same between all the CPU modules. (The module syn-
chronization setting and fixed scan communication setting need to be the same between the CPU modules
that use these functions.)
When the system parameter settings are changed, update the settings of all the CPU modules connected.
(The system parameter settings must be same in all the CPU modules.)
Details
The security key set to the program does not match the one registered to the CPU module (or extended
SRAM cassette).
Remedy
Check and correct the security key setting.
Details
The security key is set to the program, but it is not registered to the CPU module (or extended SRAM cas-
sette).
Remedy
Check and correct the security key setting.
Details
The security key set to the file is corrupted and does not match the one registered to the CPU module.
The security key registered to the CPU module is corrupted and does not match the one set to the file.
Remedy
Write the file to the CPU module again. If the same error code is displayed again, the possible cause is a
hardware failure of the CPU module. Please consult your local Mitsubishi representative.
Details
The security key is registered to the CPU module and extended SRAM cassette.
Remedy
Check and correct the security key setting.
Details
The start I/O number of the remote password target module is set to other than 0H to 0FF0H.
There is a problem on the slot specified by the start I/O number of the remote password setting.
(1) No module is mounted.
(2) The mounted intelligent function module does not support the remote password setting.
Remedy
Set the start I/O number of the remote password target module within the range 0H to 0FF0H.
On the specified slot, mount an intelligent function module that supports the remote password setting.
A01
Parameter verification error
22E0
A01
Security key authentication error
2300
A01
Security key authentication error
2301
A01
Security key authentication error
2302
A01
Security key authentication error
2303
A01
Remote A password setting error
2320
Содержание C80 Series
Страница 1: ......
Страница 7: ......
Страница 11: ......
Страница 13: ......
Страница 15: ......
Страница 18: ...1 IB 1501279 H Alarm ...
Страница 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Страница 20: ...1 3 IB 1501279 H Operation Errors M ...
Страница 54: ...2 37 IB 1501279 H Stop Codes T ...
Страница 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Страница 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Страница 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Страница 98: ...5 81 IB 1501279 H System Alarms Z ...
Страница 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Страница 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Страница 117: ...M800 M80 E80 C80 Series Alarm Parameter Manual 6 Absolute Position Detection System Alarms Z7 100 IB 1501279 H ...
Страница 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Страница 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Страница 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Страница 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Страница 136: ...11 119 IB 1501279 H Network Service Errors N ...
Страница 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Страница 140: ...12 123 IB 1501279 H Program Errors P ...
Страница 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Страница 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Страница 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Страница 216: ...199 IB 1501279 H Parameter ...
Страница 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Страница 218: ...15 201 IB 1501279 H User Parameters ...
Страница 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Страница 360: ...16 343 IB 1501279 H Machine Parameters ...
Страница 748: ......