M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
370
IB-1501279-H
[M8]
Select whether to enable or disable the stroke check before travel for skip (G31 or G31.n) and automatic tool
length measurement (G37).
0: Disable
1: Enable
(Note) This parameter is enabled when #12057=1 and the option "Stroke check before travel" is ON.
[C80]
Not used.
Specify each sub part system name.
This name is displayed when the part system acts as a sub part system.
---Setting range---
A combination of a maximum of four alpha-numeric characters
Select whether to enable variable-acceleration pre-interpolation acceleration/deceleration control while high-
accuracy control is ON.
0: Pre-interpolation acceleration/deceleration
(Apply the acceleration rate that is determined by G1bF and G1btL and is common for all the axes)
1: Variable-acceleration pre-interpolation acceleration/deceleration
(Apply the acceleration rate that is determined by G1bFx and G1btLx for each axis)
(Note) Variable-acceleration pre-interpolation acceleration/deceleration is a function available under SSS
control. To enable this function, set "#8090 SSS ON" to 1.
Specify the time constant of the filter that smoothes out fluctuations in acceleration under the tolerance con-
trol.
Basically set to 0.
---Setting range---
0 to 200 (ms)
Specify the axis address to be given in an arbitrary axis exchange command for the part system.
(Note 1) This parameter is disabled when the arbitrary axis exchange function is unused.
(Note 2) Do not give an identical name to two or more of the parameters adr_abs[1] to adr_abs[8].
(Note 3) Do not leave any unspecified parameter in the middle between adr_abs[1] and [8].
(Note 4) Set the addresses of adr_abs[ ] in the same order as of the axis names (#1013 axname). Note that
you can set a nonexistent axis name in the middle.
(Note 5) If there are 9 or more control axes per part system, specify the axis address that is programmed
based on the basic axis configuration.
---Setting range---
Axis address such as X, Y, Z, U, V, W, A, B and C
Specify the incremental command address for each of the axes to be used in an arbitrary axis exchange com-
mand.
(Note 1) This parameter is disabled when the arbitrary axis exchange function is unused.
(Note 2) There is no need to set this parameter when command type (absolute or incremental) is not distin-
guished by the axis address (when #1076 ABS/INC address=0).
(Note 3) Do not give an identical name to two or more of the parameters adr_inc[1] to adr_inc[8].
If there is any overlap, priority is given in the ascending order (adr_inc[1] to adr_inc[8]).
---Setting range---
Axis address such as X, Y, Z, U, V, W, A, B and C
#12058
OT_prechkTYPE
Stroke check before travel for skip and automatic tool
length measurement
#12059
SBS_name
Sub part system name
#12060
VblAccPreInt
Variable-acceleration pre-interpolation acceleration/de-
celeration ON
#12070
Sfilt2_tol
Tolerance control: Soft acceleration/deceleration filter
2
(PR)
#12071-12078
adr_abs[1]-[8]
Command address for arbitrary axis exchange
(PR)
#12079-12086
adr_inc[1]-[8]
Incremental command address for arbitrary axis ex-
change
Содержание C80 Series
Страница 1: ......
Страница 7: ......
Страница 11: ......
Страница 13: ......
Страница 15: ......
Страница 18: ...1 IB 1501279 H Alarm ...
Страница 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Страница 20: ...1 3 IB 1501279 H Operation Errors M ...
Страница 54: ...2 37 IB 1501279 H Stop Codes T ...
Страница 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Страница 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Страница 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Страница 98: ...5 81 IB 1501279 H System Alarms Z ...
Страница 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Страница 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Страница 117: ...M800 M80 E80 C80 Series Alarm Parameter Manual 6 Absolute Position Detection System Alarms Z7 100 IB 1501279 H ...
Страница 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Страница 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Страница 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Страница 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Страница 136: ...11 119 IB 1501279 H Network Service Errors N ...
Страница 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Страница 140: ...12 123 IB 1501279 H Program Errors P ...
Страница 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Страница 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Страница 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Страница 216: ...199 IB 1501279 H Parameter ...
Страница 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Страница 218: ...15 201 IB 1501279 H User Parameters ...
Страница 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Страница 360: ...16 343 IB 1501279 H Machine Parameters ...
Страница 748: ......