M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
349
IB-1501279-H
Set the override value when leaving the tap end point in the synchronous tapping cycle.
When "0" is set, 100 % is applied for the operation.
---Setting range---
0 to 999 (%)
Set the skip signal for ending the G04 (dwell) command.
PLC interface input signal
Skip3 Skip2 Skip1
0 : - - -
1 : - - *
2 : - * -
3 : - * *
4 : * - -
5 : * - *
6 : * * -
7 : * * *
(* : Enable - : Disable)
Set the feedrate when there is no F command in the program at G31 (skip) command.
---Setting range---
1 to 999999 (mm/min)
Designate the skip signal in multi-step skip G31.1.
The setting method is same as "#1173 dwlskp".
Set the skip feedrate in multi-step skip G31.1.
---Setting range---
1 to 999999 (mm/min)
Set the skip signal in multi-step skip G31.2.
The setting method is same as "#1173 dwlskp".
Set the skip signal in multi-step skip G31.2.
---Setting range---
1 to 999999 (mm/min)
Set the skip signal in multi-step skip G31.3
The setting method is same as "#1173 dwlskp".
Set the skip signal in multi-step skip G31.3.
---Setting range---
1 to 999999 (mm/min)
#1172
tapovr
Tap return override
#1173
dwlskp
G04 skip condition
#1174
skip_F
G31 skip speed
#1175
skip1
G31.1 skip condition
#1176
skip1f
G31.2 skip speed
#1177
skip2
G31.2 skip condition
#1178
skip2f
G31.2 skip speed
#1179
skip3
G31.3 skip condition
#1180
skip3f
G31.3 skip speed
Содержание C80 Series
Страница 1: ......
Страница 7: ......
Страница 11: ......
Страница 13: ......
Страница 15: ......
Страница 18: ...1 IB 1501279 H Alarm ...
Страница 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Страница 20: ...1 3 IB 1501279 H Operation Errors M ...
Страница 54: ...2 37 IB 1501279 H Stop Codes T ...
Страница 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Страница 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Страница 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Страница 98: ...5 81 IB 1501279 H System Alarms Z ...
Страница 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Страница 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Страница 117: ...M800 M80 E80 C80 Series Alarm Parameter Manual 6 Absolute Position Detection System Alarms Z7 100 IB 1501279 H ...
Страница 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Страница 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Страница 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Страница 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Страница 136: ...11 119 IB 1501279 H Network Service Errors N ...
Страница 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Страница 140: ...12 123 IB 1501279 H Program Errors P ...
Страница 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Страница 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Страница 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Страница 216: ...199 IB 1501279 H Parameter ...
Страница 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Страница 218: ...15 201 IB 1501279 H User Parameters ...
Страница 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Страница 360: ...16 343 IB 1501279 H Machine Parameters ...
Страница 748: ......