M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
599
IB-1501279-H
Set the vibration frequency to suppress when machine vibration occurs.
(Enabled at 50 or more.)
When not using, set to "0".
Related parameters: SP034/bit7-5
---Setting range---
0 to 5000 (Hz)
Set the inductive voltage compensation gain. Normally, set to "100".
Lower the gain when the current FB peak exceeds the current command peak.
---Setting range---
0 to 200 (%)
Set this parameter when the protrusion (that occurs due to the non-sensitive band by friction, torsion, back-
lash, etc.) at quadrant change is too large.
This sets the compensation torque at quadrant change (when an axis feed direction is reversed) by Short-
time rated %.
Whether to enable the lost motion compensation and the method can be set with other parameters.
[Type 2 "When SP033/bit9,8=10"]
Set the compensation amount based on the motor short-time rated current.
The standard setting is double of the friction torque. The compensation amount will be 0 when "0" is set.
Related parameters: SP033/bit9-8, SP039, SP040, SP041, SP227/bit2
[To vary compensation amount depending on the direction]
When SP041 (LMC2) is "0", change SP048 (LMC1) value in both of +/- directions to compensate.
To vary the compensation amount depending on the command direction, set this with SP041 (LMC2).
(SP048: + direction, SP041: - direction, However, the directions may be opposite depending on other set-
tings.)
When "-1" is set, the compensation will not be performed in the command direction.
---Setting range---
-1 to 200 (Short-time rated %)
Note that when SP227/bit2 is "1", the range will be -1 to 20000 (Short-time rated 0.01%).
When a relative error in the synchronous control is too large, set this parameter to the axis that is delaying.
The standard setting is "0". The standard setting in the SHG control is "50".
Adjust relative errors in acceleration/deceleration by increasing the value by 50.
---Setting range---
0 to 999 (%)
Set the imbalance torque.
---Setting range---
-100 to 100 (Short-time rated %)
Set the control time constant in dual feed back.
When the function is valid, the standard setting is "100". When "0" is set, the value is 1 ms.
When the time constant is increased, the operation will get closer to the semi-closed control and the limit of
the position loop gain will be raised.
However, this cannot be used when the spindle slip occurs in machine configuration such as V-belt drive.
Related parameters: SP017/bit1, SP052
---Setting range---
0 to 9999 (ms)
#13046
SP046 FHz2
Notch filter frequency 2
#13047
SP047 EC
Inductive voltage compensation gain
#13048
SP048 LMC1
Lost motion compensation 1
#13049
SP049 FFC
Acceleration rate feed forward gain
#13050
SP050 TOF
Torque offset
#13051
SP051 DFBT
Dual feed back control time constant
Содержание C80 Series
Страница 1: ......
Страница 7: ......
Страница 11: ......
Страница 13: ......
Страница 15: ......
Страница 18: ...1 IB 1501279 H Alarm ...
Страница 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Страница 20: ...1 3 IB 1501279 H Operation Errors M ...
Страница 54: ...2 37 IB 1501279 H Stop Codes T ...
Страница 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Страница 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Страница 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Страница 98: ...5 81 IB 1501279 H System Alarms Z ...
Страница 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Страница 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Страница 117: ...M800 M80 E80 C80 Series Alarm Parameter Manual 6 Absolute Position Detection System Alarms Z7 100 IB 1501279 H ...
Страница 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Страница 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Страница 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Страница 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Страница 136: ...11 119 IB 1501279 H Network Service Errors N ...
Страница 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Страница 140: ...12 123 IB 1501279 H Program Errors P ...
Страница 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Страница 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Страница 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Страница 216: ...199 IB 1501279 H Parameter ...
Страница 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Страница 218: ...15 201 IB 1501279 H User Parameters ...
Страница 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Страница 360: ...16 343 IB 1501279 H Machine Parameters ...
Страница 748: ......