M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
387
IB-1501279-H
Select how to handle the absolute position data during automatic handle interrupt.
0: Absolute position data will be renewed if manual ABS switch is ON. If it is OFF, data won't be renewed.
1: Follow the "intabs" state when "#1061 intabs" is enabled
Select how to handle the spindle rotation speed clamp function with the G92/G50S command.
0: G92/G50S command is handled as a clamp command only in the G96 state (during constant surface
speed control).
G92S will be handled as normal S command in G97 state (constant surface speed OFF).
1: The S command in the same block as G92/G50 is constantly handled as a clamp command
Specify the type of spindle min. rotation speed clamp value.
0: Rotation speed setting
1: Output voltage coefficient setting
Set "#3023 smini" according to this type setting.
Select whether to decelerate at the arc entrance or exit.
0: Not decelerate
1: Decelerate
Select whether to perform a deceleration check or in-position check at the hole bottom in a hole drilling cycle.
This parameter is enabled only for a hole drilling cycle in which no dwell command can be issued at the hole
bottom.
0: Perform no deceleration check and in-position check
1: Perform deceleration check
2: Perform in-position check
Not used. Set to "0".
Not used. Set to "100".
Not used. Set to "100".
Not used. Set to "0".
Not used. Set to "0".
Select whether to enable or disable RIO connection detection.
0: Enable
1: Disable
If your I/O consists of only cards such as CC-LINK, setting this parameter to "1" will avoid the RIO commu-
nication cutoff alarm.
Select whether to enable or disable the automatic tuning function.
0: Disable
1: Enable
(Note) Enable this parameter when using MS Configurator.
#1145
I_abs
Manual ABS parameter
#1146
Sclamp
Spindle rotation speed clamp function
#1147
smin_V
Minimum spindle rotation speed clamp type
#1149
cireft
Arc deceleration speed change
#1153
FixbDc
Hole bottom deceleration check
(PR)
#1154
pdoor
#1155
DOOR_m
#1156
DOOR_s
#1157
F0atrn
#1158
F0atno
(PR)
#1163
No rio
RIO connection detection invalid
(PR)
#1164
ATS
Automatic tuning function
Содержание C80 Series
Страница 1: ......
Страница 7: ......
Страница 11: ......
Страница 13: ......
Страница 15: ......
Страница 18: ...1 IB 1501279 H Alarm ...
Страница 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Страница 20: ...1 3 IB 1501279 H Operation Errors M ...
Страница 54: ...2 37 IB 1501279 H Stop Codes T ...
Страница 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Страница 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Страница 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Страница 98: ...5 81 IB 1501279 H System Alarms Z ...
Страница 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Страница 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Страница 117: ...M800 M80 E80 C80 Series Alarm Parameter Manual 6 Absolute Position Detection System Alarms Z7 100 IB 1501279 H ...
Страница 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Страница 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Страница 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Страница 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Страница 136: ...11 119 IB 1501279 H Network Service Errors N ...
Страница 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Страница 140: ...12 123 IB 1501279 H Program Errors P ...
Страница 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Страница 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Страница 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Страница 216: ...199 IB 1501279 H Parameter ...
Страница 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Страница 218: ...15 201 IB 1501279 H User Parameters ...
Страница 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Страница 360: ...16 343 IB 1501279 H Machine Parameters ...
Страница 748: ......