M800/M80/E80/C80 Series Alarm/Parameter Manual
10 User PLC Alarms (U)
117
IB-1501279-H
Details
Software exceptional interruption (Unmounted instruction error) has occurred.
(1) When the bit selection parameter (#6452 bit6) "branch destination label check valid" is set to "0", jumped to
an undefined label.
(2) Sequence program in execution is broken.
Remedy
(1) Set the bit selection parameter (#6452 bit6) "branch destination label check valid" to "1" and check the
branching step to the undefined label.
(2) Contact Mitsubishi.
Details
Software exceptional interruption (Instruction format error) has occurred.
Remedy
Contact Mitsubishi.
Details
Software exceptional interruption (Instruction bus error) has occurred.
(1) When the bit selection parameter (#6452 bit6) "branch destination label check valid" is set to "0", jumped to
an undefined label.
(2) Sequence program in execution is broken.
Remedy
(1) Set the bit selection parameter (#6452 bit6) "branch destination label check valid" to "1" and check the
branching step to the undefined label.
(2) Contact Mitsubishi.
Details
Software exceptional interruption (CALL/RET instruction error) has occurred.
Remedy
Contact Mitsubishi.
Details
Software exceptional interruption (memory area error) has occurred.
Remedy
Contact Mitsubishi.
Details
Software exceptional interruption (ASYNC BUS error) has occurred.
Remedy
Contact Mitsubishi.
Details
The ladder is stopped.
Remedy
Run the PLC.
U10
Illegal PLC
0x83xx.yy
Number of steps
U10
Illegal PLC
0x84xx.yy
Number of steps
U10
Illegal PLC
0x85xx.yy
Number of steps
U10
Illegal PLC
0x86xx.yy
Number of steps
U10
Illegal PLC
0x87xx.yy
Number of steps
U10
Illegal PLC
0x8Bxx.yy
Number of steps
U50
PLC stopped
Содержание C80 Series
Страница 1: ......
Страница 7: ......
Страница 11: ......
Страница 13: ......
Страница 15: ......
Страница 18: ...1 IB 1501279 H Alarm ...
Страница 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Страница 20: ...1 3 IB 1501279 H Operation Errors M ...
Страница 54: ...2 37 IB 1501279 H Stop Codes T ...
Страница 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Страница 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Страница 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Страница 98: ...5 81 IB 1501279 H System Alarms Z ...
Страница 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Страница 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Страница 117: ...M800 M80 E80 C80 Series Alarm Parameter Manual 6 Absolute Position Detection System Alarms Z7 100 IB 1501279 H ...
Страница 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Страница 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Страница 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Страница 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Страница 136: ...11 119 IB 1501279 H Network Service Errors N ...
Страница 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Страница 140: ...12 123 IB 1501279 H Program Errors P ...
Страница 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Страница 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Страница 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Страница 216: ...199 IB 1501279 H Parameter ...
Страница 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Страница 218: ...15 201 IB 1501279 H User Parameters ...
Страница 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Страница 360: ...16 343 IB 1501279 H Machine Parameters ...
Страница 748: ......