M800/M80/E80/C80 Series Alarm/Parameter Manual
13 Smart Safety Observation Alarm (V)
169
IB-1501279-H
Details
The channel No. or station No. of the emergency stop signal device (set by parameters) does not coincide with
any contact point (channel/station No. specified by the safety I/O assignment parameters RIO CH No and RIO
Station No.) of the safety I/O unit. The screen displays the index No. of the incorrectly set emergency stop sig-
nal device.
0001: EMG_Dev1_ch to EMG_Dev1_bit
0002: EMG_Dev2_ch to EMG_Dev2_bit
Remedy
Change the channel, station or bit No. of emergency stop signal device to be one of the contact points of
the safety I/O unit. And then turn OFF and ON the power.
When you change the setting of emergency stop signal device channel No. (EMG_Dev1_ch /
EMG_Dev2_ch) to 0, and turn OFF and ON the power, the designation of emergency stop signal device is
disabled, so this alarm is cleared.
Details
Safety I/O device assignment parameter is incorrect.
The safety I/O device assignment parameter of the connected safety I/O unit is not set.
The safety I/O device assignment parameter is set for any disconnected safety I/O unit.
The set channel No. or station No. is overlapped.
Remedy
Make sure which safety I/O unit is connected, set the safety I/O device assignment parameters, and then
turn OFF and ON the power.
Details
There is a discrepancy between the PLC side parameter (I/O allocation setting) and CNC side parameter (safe-
ty I/O allocation).
The setting of "Top XY" on the PLC side is different from "DI(DO) dev No." on the CNC side.
The number of registered safety signal units is different between PLC and CNC sides.
Remedy
Correct the parameters to be consistent between PLC and CNC. After that turn OFF and ON the CNC power.
Details
During SLS observation, the command/FB speed has exceeded the safely-limited speed(*) and has not
dropped below the speed limit within the SLS detection delay time (set by parameter).
The screen displays the name of axis of this error.
(*)Safely-limited speed = SLS speed tolerance x SLS speed override / 100
Remedy
This error can be cancelled by the safety reset signal while motor speed is under SLS limit.
If the SLS speed tolerance or SLS speed override (set by parameter) is lower than the assumption, change
the parameter setting and turn OFF and ON the power.
If the SLS detection delay time (set by parameter) is shorter than the assumption, change the parameter
setting.
Check the safety ladder to make sure that SLS speed tolerance and SLS speed override are changed in
a timely manner.
V04
EMG stop signal device illegal
0007
Emergency stop device
index No.
V04
Safe IO assign para setting er
0009
Channel No.
V04
Safety I/O param inconsistent
0011
V05
SLS speed error
0001
Axis name
Содержание C80 Series
Страница 1: ......
Страница 7: ......
Страница 11: ......
Страница 13: ......
Страница 15: ......
Страница 18: ...1 IB 1501279 H Alarm ...
Страница 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Страница 20: ...1 3 IB 1501279 H Operation Errors M ...
Страница 54: ...2 37 IB 1501279 H Stop Codes T ...
Страница 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Страница 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Страница 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Страница 98: ...5 81 IB 1501279 H System Alarms Z ...
Страница 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Страница 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Страница 117: ...M800 M80 E80 C80 Series Alarm Parameter Manual 6 Absolute Position Detection System Alarms Z7 100 IB 1501279 H ...
Страница 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Страница 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Страница 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Страница 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Страница 136: ...11 119 IB 1501279 H Network Service Errors N ...
Страница 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Страница 140: ...12 123 IB 1501279 H Program Errors P ...
Страница 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Страница 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Страница 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Страница 216: ...199 IB 1501279 H Parameter ...
Страница 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Страница 218: ...15 201 IB 1501279 H User Parameters ...
Страница 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Страница 360: ...16 343 IB 1501279 H Machine Parameters ...
Страница 748: ......