M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
701
IB-1501279-H
Specify the upper limits of machine-end speed determined as safe for each of SSM speeds 1 to 4. If the com-
mand/FB speed is at the safe speed or lower while SSM is ON, the Under SSM safe speed signal turns ON.
If the command/FB speed exceeds the safe speed, the Under SSM safe speed signal turns OFF. The safe
speed to be applied to SSM is calculated using the following equation.
(When the Under SSM safe speed signal is ON)
Safe speed = SSM speed
(When the Under SSM safe speed signal is OFF)
Safe speed = SSM speed - SSM hysteresis width
---Setting range---
0 to 999999.9 (r/min)
Specify the hysteresis widths that correspond to SSM speeds 1 to 4. For details refer to SSM speeds 1 to 4.
---Setting range---
0 to 999999.9 (r/min)
Specify the upper limit of machine-end speed determined as a safe operating stop.
If the SOS_V detection delay time has elapsed with the command/FB speed exceeding that of this pa-
rameter while SOS is ON, a safe stop (SS1 or STO) is executed.
The point of time at which the command/FB speed drops to that of this parameter or lower while SS1/
SS2 is ON is treated as a standstill.
*When this parameter is set to 0, "SOS speed error" may occur even though the spindle is at a standstill.
---Setting range---
0 to 9999.9 (r/min)
Specify a period of time to detect a speed error while SOS is ON. If the period of time set in this parameter
has elapsed with the command/FB speed exceeding the SOS stop speed while SOS is ON, a safe stop (SS1
or STO) is executed.
---Setting range---
0 to 9999 (ms)
Specify the upper limit of machine-end position deviation determined as a safe operating stop. If the SOS_PD
detection delay time has elapsed with the position deviation (difference between the command and FB posi-
tions) exceeding that of this parameter while SOS is ON, a safe stop (SS1 or STO) is executed.
* When this parameter is set to 0, "SOS position deviation error" may occur even though the spindle is at a
standstill.
---Setting range---
0 to 9999 (°)
Specify a period of time to detect a position deviation error while SOS is ON. If the time set in this parameter
has elapsed with the position deviation (difference between the command and FB positions) exceeding the
SOS position deviation tolerance while SOS is ON, a safe stop (SS1 or STO) is executed.
---Setting range---
0 to 9999 (ms)
Specify the upper limit of machine-end travel distance (minus side) determined as a safe operating stop. If
the SOS_P detection delay time has elapsed with the command/FB travel distance in the minus direction ex-
ceeding that of this parameter while SOS is ON, a safe stop (SS1 or STO) is executed.
*When this parameter is set to 0, "SOS travel distance error" may occur even though the spindle is at a stand-
still.
---Setting range---
0 to 9999 (°)
(PR)
#51326-
51329
SSM_SSpeed1-4
SSM speed 1-4
#51330-
51333
SSM_SHysteresis1-4
SM hysteresis width 1-4
(PR)
#51334
SOS_SSpeed
SOS stop speed
#51335
SOS_ST1
SOS_V detection delay time
(PR)
#51336
SOS_SDroop
SOS position deviation tolerance
#51337
SOS_ST2
SOS_PD detection delay time
(PR)
#51338
SOS_SPositionM
SOS travel distance tolerance (-)
Содержание C80 Series
Страница 1: ......
Страница 7: ......
Страница 11: ......
Страница 13: ......
Страница 15: ......
Страница 18: ...1 IB 1501279 H Alarm ...
Страница 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Страница 20: ...1 3 IB 1501279 H Operation Errors M ...
Страница 54: ...2 37 IB 1501279 H Stop Codes T ...
Страница 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Страница 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Страница 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Страница 98: ...5 81 IB 1501279 H System Alarms Z ...
Страница 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Страница 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Страница 117: ...M800 M80 E80 C80 Series Alarm Parameter Manual 6 Absolute Position Detection System Alarms Z7 100 IB 1501279 H ...
Страница 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Страница 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Страница 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Страница 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Страница 136: ...11 119 IB 1501279 H Network Service Errors N ...
Страница 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Страница 140: ...12 123 IB 1501279 H Program Errors P ...
Страница 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Страница 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Страница 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Страница 216: ...199 IB 1501279 H Parameter ...
Страница 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Страница 218: ...15 201 IB 1501279 H User Parameters ...
Страница 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Страница 360: ...16 343 IB 1501279 H Machine Parameters ...
Страница 748: ......