M800/M80/E80/C80 Series Alarm/Parameter Manual
1 Operation Errors (M)
33
IB-1501279-H
Details
Spindle synchronization cancel command has been issued during rotation of C axis under spindle sync C
axis control.
G113 (without the address H or D) has been issued during the spindle synchronization for two or more
sync sets.
Remedy
This operation error is cancelled when C axis stops. Issue a spindle sync cancel command after C axis
has stopped.
Use G113D or G113H to cancel the spindle synchronization.
Details
The guide bushing spindle synchronization temporary cancel signal was turned ON/OFF when the master spin-
dle and the guide bushing spindle were in one of the following modes.
During rotation (when not stopped)
During tap cycle synchronization mode
During spindle synchronization mode
During tool-spindle synchronization I (polygon machining) mode
During tool-spindle synchronization II (hobbing) mode
During spindle C axis control C axis mode
During orientation/indexing
Remedy
Check the ladder program.
Details
The reference spindle was commanded as a spindle related to tool spindle synchronization IC (polygon).
The guide bushing spindle was commanded as a synchronous tapping spindle.
The guide bushing spindle was commanded as a spindle related to spindle synchronization/tool spindle
synchronization I (polygon)/tool spindle synchronization II (hobbing).
Remedy
Check the program.
Details
Synchronous tapping was issued for the reference spindle or the synchronized spindle during spindle synchro-
nization.
Remedy
Cancel the synchronous tapping.
Details
An axis in STO state exists in the part system.
Remedy
Release the STO state and reset the NC.
Details
When the NC reset signal is input with the High-speed simple program check: Coordinate position check ON
signal (Y76B) set to ON, the workpiece coordinate position is different from the position at the program start.
Remedy
Correct the machining program.
M01
Spindle sync cancel error
1135
M01
GB SP sync:Cancel sgnl illegal
1137
M01
GB SP sync runs independently
1138
M01
Cmds illegal in spindle synchr
1139
M01
Operation non-continuable(STO)
1151
M01
Prog check: work posn error
1215
Содержание C80 Series
Страница 1: ......
Страница 7: ......
Страница 11: ......
Страница 13: ......
Страница 15: ......
Страница 18: ...1 IB 1501279 H Alarm ...
Страница 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Страница 20: ...1 3 IB 1501279 H Operation Errors M ...
Страница 54: ...2 37 IB 1501279 H Stop Codes T ...
Страница 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Страница 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Страница 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Страница 98: ...5 81 IB 1501279 H System Alarms Z ...
Страница 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Страница 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Страница 117: ...M800 M80 E80 C80 Series Alarm Parameter Manual 6 Absolute Position Detection System Alarms Z7 100 IB 1501279 H ...
Страница 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Страница 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Страница 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Страница 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Страница 136: ...11 119 IB 1501279 H Network Service Errors N ...
Страница 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Страница 140: ...12 123 IB 1501279 H Program Errors P ...
Страница 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Страница 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Страница 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Страница 216: ...199 IB 1501279 H Parameter ...
Страница 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Страница 218: ...15 201 IB 1501279 H User Parameters ...
Страница 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Страница 360: ...16 343 IB 1501279 H Machine Parameters ...
Страница 748: ......