M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
305
IB-1501279-H
Select which spindle to display in the 6th part system window for the 2-, 3- or 4-part system simultaneous
display.
(Note 1) If you select "00" for the 2-, 3- or 4-part system simultaneous display, the default display is used (1st
spindle on the upper side and 2nd spindle on the lower side).
(Note 2) If you set the same number as, or a greater number than the setting of "#1039 spinno", or if the high-
or low-order setting is "0", the 1st spindle is displayed.
(Note 3) If you set the low-order to F, the screen shows the actual rotation speed, command speed and load
meter of the high-order spindle.
Note that for the 4-counter display in 4-part system simultaneous display, even if the low-order is not
F, the screen shows the actual rotation speed, command speed and load meter of the high-order
and low-order spindles.
(Note 4) [M8] 3- or 4-part system simultaneous display is enabled for a 15- or 19-type display unit only.
[C80] 3- or 4-part system simultaneous display is not available.
---Setting range---
High-order(Select an upper side spindle.): 0 to 8
Low-order(Select a lower side spindle.): 0 to 8, F
Select which spindle to display in the 7th part system window for the 2-, 3- or 4-part system simultaneous
display.
(Note 1) If you select "00" for the 2-, 3- or 4-part system simultaneous display, the default display is used (1st
spindle on the upper side and 2nd spindle on the lower side).
(Note 2) If you set the same number as, or a greater number than the setting of "#1039 spinno", or if the high-
or low-order setting is "0", the 1st spindle is displayed.
(Note 3) If you set the low-order to F, the screen shows the actual rotation speed, command speed and load
meter of the high-order spindle.
Note that for the 4-counter display in 4-part system simultaneous display, even if the low-order is not
F, the screen shows the actual rotation speed, command speed and load meter of the high-order
and low-order spindles.
(Note 4) [M8] 3- or 4-part system simultaneous display is enabled for a 15- or 19-type display unit only.
[C80] 3- or 4-part system simultaneous display is not available.
---Setting range---
High-order(Select an upper side spindle.): 0 to 8
Low-order(Select a lower side spindle.): 0 to 8, F
[M8]
Select which spindle to display in the 8th part system window for the 2-, 3- or 4-part system simultaneous
display.
(Note 1) If you select "00" for the 2-, 3- or 4-part system simultaneous display, the default display is used (1st
spindle on the upper side and 2nd spindle on the lower side).
(Note 2) If you set the same number as, or a greater number than the setting of "#1039 spinno", or if the high-
or low-order setting is "0", the 1st spindle is displayed.
(Note 3) If you set the low-order to F, the screen shows the actual rotation speed, command speed and load
meter of the high-order spindle.
Note that for the 4-counter display in 4-part system simultaneous display, even if the low-order is not
F, the screen shows the actual rotation speed, command speed and load meter of the high-order
and low-order spindles.
(Note 4) 3- or 4-part system simultaneous display is enabled for a 15- or 19-type display unit only.
---Setting range---
High-order(Select an upper side spindle.): 0 to 8
Low-order(Select a lower side spindle.): 0 to 8, F
[C80]
Not used.
#8959
SP on 6th part sys
#8960
SP on 7th part sys
#8961
SP on 8th part sys
Содержание C80 Series
Страница 1: ......
Страница 7: ......
Страница 11: ......
Страница 13: ......
Страница 15: ......
Страница 18: ...1 IB 1501279 H Alarm ...
Страница 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Страница 20: ...1 3 IB 1501279 H Operation Errors M ...
Страница 54: ...2 37 IB 1501279 H Stop Codes T ...
Страница 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Страница 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Страница 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Страница 98: ...5 81 IB 1501279 H System Alarms Z ...
Страница 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Страница 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Страница 117: ...M800 M80 E80 C80 Series Alarm Parameter Manual 6 Absolute Position Detection System Alarms Z7 100 IB 1501279 H ...
Страница 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Страница 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Страница 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Страница 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Страница 136: ...11 119 IB 1501279 H Network Service Errors N ...
Страница 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Страница 140: ...12 123 IB 1501279 H Program Errors P ...
Страница 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Страница 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Страница 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Страница 216: ...199 IB 1501279 H Parameter ...
Страница 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Страница 218: ...15 201 IB 1501279 H User Parameters ...
Страница 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Страница 360: ...16 343 IB 1501279 H Machine Parameters ...
Страница 748: ......