M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
228
IB-1501279-H
Select whether to apply dry run (feed at manual setting speed instead of command feedrate) to the G00 com-
mand.
0: Not apply to G00. (move at rapid traverse rate)
1: Apply to G00. (move at manual setting speed)
Select the G00 travel path type.
0: Move linearly toward the end point. (interpolation type)
1: Move to the end point of each axis at the rapid traverse feedrate for each axis. (non-interpolation)
(Note) If this parameter is set to "1", neither of the following functions will be available: rapid traverse constant
inclination acceleration/deceleration and rapid traverse constant inclination multi-step acceleration/decel-
eration.
Select the modal state at power ON from among the following: high-accuracy control mode, high-speed high-
accuracy control I mode, high-speed high-accuracy control II mode or high-speed high-accuracy control III
mode.
0: G08P0/G64 (cutting) mode
1: G08P1/G61.1 (high-accuracy control) mode
2: G05.1Q1 (high-speed high-accuracy control I) mode
3: G05P10000 (high-speed high-accuracy control II) mode
4: G05P20000 (high-speed high-accuracy control III) mode
Select whether to clear or hold the interruption amount after the "NC reset 1 (or 2)" signal is ON when the
manual ABS switch is OFF.
0: Clear (Reset the coordinate deviation due to the interruption)
1: Hold
Select the measurement operation for mirror-imaged axes during the manual tool length measurement 1 or 2.
0: Set the measurement result as the tool length.
1: Reverse the sign of measurement result and set it as the tool length.
#1085
G00Drn
G00 dry run
#1086
G0lntp
G00 non-interpolation
#1148
I_G611
Initial hi-precis
#8173
Hold intr amount
#8174
T meas. in mirror
Содержание C80 Series
Страница 1: ......
Страница 7: ......
Страница 11: ......
Страница 13: ......
Страница 15: ......
Страница 18: ...1 IB 1501279 H Alarm ...
Страница 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Страница 20: ...1 3 IB 1501279 H Operation Errors M ...
Страница 54: ...2 37 IB 1501279 H Stop Codes T ...
Страница 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Страница 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Страница 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Страница 98: ...5 81 IB 1501279 H System Alarms Z ...
Страница 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Страница 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Страница 117: ...M800 M80 E80 C80 Series Alarm Parameter Manual 6 Absolute Position Detection System Alarms Z7 100 IB 1501279 H ...
Страница 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Страница 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Страница 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Страница 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Страница 136: ...11 119 IB 1501279 H Network Service Errors N ...
Страница 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Страница 140: ...12 123 IB 1501279 H Program Errors P ...
Страница 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Страница 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Страница 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Страница 216: ...199 IB 1501279 H Parameter ...
Страница 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Страница 218: ...15 201 IB 1501279 H User Parameters ...
Страница 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Страница 360: ...16 343 IB 1501279 H Machine Parameters ...
Страница 748: ......