v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 4, “Parts listing,” on page 109 to determine which components are customer replaceable
units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
0011002
Microprocessor mismatch
1. Run the Setup utility and view the microprocessor
information to compare the installed microprocessor
specifications.
2. (Trained service technician only) Remove and replace
one of the microprocessors so that they both match.
0011004
Microprocessor failed BIST
1. Update the system firmware (see “Firmware updates” on
2. (Trained service technician only) Reseat microprocessor
2.
3. Replace the following components one at a time, in the
order shown, restarting the system-board tray each time:
a. (Trained service technician only) Microprocessor
b. (Trained service technician only) System board
001100A
Microcode update failed
1. Update the system firmware (see “Firmware updates” on
2. (Trained service technician only) Replace the
microprocessor.
0050001
DIMM disabled
Note:
Each time you install or remove a DIMM, you must
disconnect the server from the power source; then, wait 10
seconds before restarting the server.
1. Make sure the DIMM is installed correctly (see “Installing
a memory module” on page 164).
2. If the DIMM was disabled because of a memory fault,
follow the suggested actions for that error event and
restart the server.
3. Check the IBM support website for an applicable retain tip
or firmware update that applies to this memory event. If
no memory fault is recorded in the logs and no DIMM
connector error LED is lit, you can re-enable the DIMM
through the Setup utility or the Advanced Settings Utility
(ASU).
Chapter 3. Diagnostics
17
Содержание System x iDataPlex dx360 M2
Страница 2: ......
Страница 16: ...xiv System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 138: ...122 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 256: ...240 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 262: ...246 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 263: ......
Страница 264: ...Part Number 00D3199 Printed in USA 1P P N 00D3199...