Table 3. Integrated management module error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 4, “Parts listing,” on page 109 to determine which components are customer replaceable
units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Message
Severity
Description
Action
The Processor CPU
n
Status has Failed with
IERR.
(
n
= microprocessor number)
Error
A processor failed - IERR condition
has occurred.
1. Make sure that the latest levels
of firmware and device drivers
are installed for all adapters and
standard devices, such as
Ethernet, SCSI, and SAS.
Important:
Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part of
a cluster solution, verify that the
latest level of code is supported
for the cluster solution before
you update the code.
2. Run the DSA program for the
hard disk drives and other I/O
devices.
3. (Trained service technician only)
Replace microprocessor
n
.
(
n
= microprocessor number)
The System %1 encountered
a POST Error.
(%1 =
CIM_ComputerSystem.
ElementName)
Error
A POST error has occurred.
(Sensor = Firmware Error)
1. Update the UEFI firmware on
the primary page.
Important:
Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part of
a cluster solution, verify that the
latest level of code is supported
for the cluster solution before
you update the code.
2. (Trained service technician only)
Replace the system board.
The System %1 encountered
a POST Error.
(%1 =
CIM_ComputerSystem.
ElementName)
Error
A POST error has occurred.
(Sensor = ABR Status)
1. Recover the UEFI firmware
from the backup page:
a. Restart the server.
b. At the prompt, press F3 to
recover the firmware.
2. Update the UEFI firmware to
the latest level.
Important:
Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part of
a cluster solution, verify that the
latest level of code is supported
for the cluster solution before
you update the code.
104
System x iDataPlex dx360 M2: Problem Determination and Service Guide
Содержание System x iDataPlex dx360 M2
Страница 2: ......
Страница 16: ...xiv System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 138: ...122 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 256: ...240 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 262: ...246 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 263: ......
Страница 264: ...Part Number 00D3199 Printed in USA 1P P N 00D3199...