Removing the 2U chassis fan assembly
To remove the 2U chassis fan assembly, complete the following steps.
Fan assembly
1. Read the safety information that begins on page vii and “Installation guidelines”
2. If the chassis that contains the fan assembly is installed in an iDataPlex rack,
remove it (see “Removing the 2U chassis from a Type 7825 iDataPlex rack” on
page 186).
3. Remove any installed system-board trays (see “Removing the system-board tray
from a 2U chassis” on page 126).
4. Remove the top cover (see “Removing the 2U chassis fan-assembly top cover”
5. Grasp the tab at each end of the fan assembly and lift it out of the chassis.
6. If you are instructed to return the fan assembly, follow all packaging instructions,
and use any packaging materials for shipping that are supplied to you.
Chapter 5. Removing and replacing server components
133
Содержание System x iDataPlex dx360 M2
Страница 2: ......
Страница 16: ...xiv System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 138: ...122 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 256: ...240 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 262: ...246 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 263: ......
Страница 264: ...Part Number 00D3199 Printed in USA 1P P N 00D3199...