Installing the 3U chassis fan assembly
To install the 3U chassis fan assembly, complete the following steps.
1. Touch the static-protective package that contains the fan assembly to any
unpainted
metal surface on the outside of the chassis; then, remove the fan
assembly from the package.
2. Orient the fan assembly over the opening in the chassis. Make sure that the
power connector on the fan assembly aligns with the connector on the power
supply.
3. Route any cables through the fan assembly.
4. Lower the fan assembly into the chassis and press down on the tab above the
power connector and make sure that it is fully seated.
5. Install the retention bracket.
6. Install the storage-riser-card assembly and ServeRAID SAS controller (see
7. Install the top cover (see “Installing the 3U chassis top cover” on page 137).
8. Install the 3U chassis in the iDataPlex rack (see “Installing the 3U chassis top
Removing and installing an adapter