Table 3. Integrated management module error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 4, “Parts listing,” on page 109 to determine which components are customer replaceable
units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Message
Severity
Description
Action
Memory uncorrectable error
detected for DIMM
n
Status
on Memory Subsystem
DIMM
n
Status.
(
n
= DIMM number)
Error
A memory uncorrectable error has
occurred.
5. (Trained service technician only)
If the problem occurs on the
same DIMM connector, check
the DIMM connector. If the
connector contains any foreign
material or is damaged, replace
the system-board tray (see
“Removing the system-board
tray” on page 208 and
“Installing the system-board
tray” on page 210).
6. (Trained service technician only)
Remove the affected
microprocessor and check the
microprocessor socket pins for
any damaged pins. If a damage
is found, replace the
system-board tray (see
“Removing the system-board
tray” on page 208 and
“Installing the system-board
tray” on page 210).
7. (Trained Service technician
only) Replace the affected
microprocessor (see “Removing
a microprocessor and heat sink”
on page 197 and “Installing a
microprocessor and heat sink”
on page 199).
Chapter 3. Diagnostics
93
Содержание System x iDataPlex dx360 M2
Страница 2: ......
Страница 16: ...xiv System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 138: ...122 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 256: ...240 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 262: ...246 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 263: ......
Страница 264: ...Part Number 00D3199 Printed in USA 1P P N 00D3199...