Table 3. Integrated management module error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 4, “Parts listing,” on page 109 to determine which components are customer replaceable
units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Message
Severity
Description
Action
Failure Predicted on drive n
for array %1.
(n = hard disk drive number,
%1 = CIM_ComputerSystem.
ElementName)
Warning
Predicted failure on a drive.
1. Run the hard disk drive
diagnostic test on drive
n
.
2. Reseat the following
components:
a. Hard disk drive
b. Cable from the system
board to the backplane
3. Replace the following
components one at a time, in
the order shown, restarting the
server each time:
a. Hard disk drive
b. Cable from the system
board to the backplane
c. Hard disk drive backplane
Fault in slot System board
on system %1. (%1 =
CIM_ComputerSystem.
ElementName)
Error
A PCI slot error has occurred.
1. Check the riser-card LEDs.
2. Reseat the affected adapters
and riser card.
3. Update the server and adapter
firmware (UEFI and IMM).
Important:
Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part of
a cluster solution, verify that the
latest level of code is supported
for the cluster solution before
you update the code.
4. Remove both adapters.
5. Replace the PCIe adapter.
6. Replace the riser card.
7. (Trained service technician only)
Replace the system board.
Flash of %1 from %2 failed
for user %3. (%1 =
CIM_ManagedElement.
ElementName;
%2 = Web or LegacyCLI;
%3 = user ID)
Info
An attempt to update a firmware
component from the interface and
IP address has failed.
Try to update the firmware again.
84
System x iDataPlex dx360 M2: Problem Determination and Service Guide
Содержание System x iDataPlex dx360 M2
Страница 2: ......
Страница 16: ...xiv System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 138: ...122 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 256: ...240 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 262: ...246 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 263: ......
Страница 264: ...Part Number 00D3199 Printed in USA 1P P N 00D3199...