1. Read the safety information that begins on page vii and “Installation guidelines”
2. If the chassis that contains the power supply is installed in an iDataPlex rack,
remove it (see “Removing the 2U chassis from a Type 7825 iDataPlex rack” on
page 186).
3. Remove the top cover (see “Removing the 2U chassis fan-assembly top cover”
4. Remove the fan assembly (see “Removing the 2U chassis fan assembly” on
5. Press the power-supply release latch and push the power supply toward the
front of the chassis.
6. Carefully pull the power supply out through the front of the chassis.
7. If you are instructed to return the power supply, follow all packaging instructions,
and use any packaging materials for shipping that are supplied to you.
Installing a power supply in a 2U chassis
To install the power supply in a 2U chassis, complete the following steps.
Release
latch
Power supply
Power supply
1. Touch the static-protective package that contains the power supply to any
unpainted
metal surface on the outside of the chassis; then, remove the power
supply from the package.
2. Insert the power supply into the front of the chassis.
3. Carefully guide the power supply into the guides at the left-rear corner of the
chassis until the release latch clicks into place.
4. Install the fan assembly (see “Installing the 2U chassis fan assembly” on page
5. Install the top cover (see “Installing the 2U chassis fan-assembly top cover” on
6. Install the chassis in the iDataPlex rack (see “Installing the 2U chassis in a Type
7825 iDataPlex rack” on page 187).
Removing a power supply from a 3U chassis
To remove a power supply from a 3U chassis, complete the following steps:
1. Read the safety information that begins on page vii and “Installation guidelines”
174
System x iDataPlex dx360 M2: Problem Determination and Service Guide
Содержание System x iDataPlex dx360 M2
Страница 2: ......
Страница 16: ...xiv System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 138: ...122 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 256: ...240 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 262: ...246 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 263: ......
Страница 264: ...Part Number 00D3199 Printed in USA 1P P N 00D3199...