b. Install the system-board tray in the chassis (see “Installing the system-board
tray in a 2U chassis” on page 127).
6. If you are installing the hard disk drive bracket and cable assembly in an I/O
enclosure, complete the following steps:
a. Install the I/O enclosure on the system-board tray (see “Installing an
expansion enclosure on a system-board tray” on page 132).
b. Install the system-board tray in the chassis (see “Installing the system-board
tray in a 2U chassis” on page 127).
7. If you are instructed to return the hard disk drive bracket and cable assembly,
follow all packaging instructions, and use any packaging materials for shipping
that are supplied to you.
Removing a four-bay hard disk drive bracket and cable assembly
To remove a four-bay hard disk drive bracket and cable assembly from the storage
enclosure, complete the following steps.
Storage
enclosure
Hard disk drive bracket
and cable assembly
Release latch
Release latch
1. Read the safety information that begins on page vii and “Installation guidelines”
2. If the system-board tray is installed in a chassis, remove it (see “Removing the
system-board tray from a 2U chassis” on page 126).
3. Remove the storage enclosure from the system-board tray (see “Removing an
expansion enclosure from a system-board tray” on page 131).
4. Carefully set the storage enclosure on a flat, static-protective surface.
5. If hard disk drives are installed in the storage enclosure, make note of where
the drives are installed; then, remove them (see “Removing a 3.5-inch
simple-swap hard disk drive” on page 142).
6. Make a note of where the hard disk drive bracket and cable assembly cables
are attached; then, disconnect them.
7. Press inward on the hard disk drive bracket and cable assembly release
latches; then, lift the hard disk drive bracket and cable assembly off the
mounting tabs and out of the storage enclosure.
170
System x iDataPlex dx360 M2: Problem Determination and Service Guide
Содержание System x iDataPlex dx360 M2
Страница 2: ......
Страница 16: ...xiv System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 138: ...122 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 256: ...240 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 262: ...246 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 263: ......
Страница 264: ...Part Number 00D3199 Printed in USA 1P P N 00D3199...