1. Read the safety information that begins on page vii and “Installation guidelines”
2. If the 3U chassis is installed in an iDataPlex rack, remove it (see “Removing a
3U chassis from a Type 7825 iDataPlex rack” on page 190).
3. Remove the top cover (see “Removing the 3U chassis top cover” on page
4. Note the signal cable routing and connection locations; then, disconnect the
signal cables from the assembly.
Attention:
When you move the storage-riser-card assembly, do not allow it
to touch any components or structures inside the 3U chassis.
5. Lift up on the storage-riser-card assembly.
6. Turn the storage-riser-card assembly to access the ServeRAID SAS controller.
7. Pull the controller from the connector on the storage-riser-card assembly.
8. Disconnect the battery cable from the battery cable interposer card.
182
System x iDataPlex dx360 M2: Problem Determination and Service Guide