Installing a 3U chassis in a Type 7825 iDataPlex rack
To install the 3U chassis in a Type 7825 iDataPlex rack, complete the following
steps.
1. Align the 3U chassis with the rails on the iDataPlex rack; then, slide the 3U
chassis into the rack until it is fully seated.
2. Install the M6 screws that secure the chassis to the rack.
3. Install the hard disk drives (see “Removing and installing a hard disk drive” on
4. Reconnect the cables on the front of the system-board tray.
5. Turn on the system-board tray (see “Turning on the system-board tray” on page
6. Make sure that the power-on LED on the system-board tray operator panel is lit
continuously, indicating that the system-board tray is receiving power and is
turned on.
If you have changed the configuration of the system-board tray, you might have to
update the server configuration through the Setup utility (see “Using the Setup
utility” on page 214).
Chapter 5. Removing and replacing server components
191