1. Touch the static-protective package that contains the hard disk drive to any
unpainted
metal surface on the outside of the chassis or rack; then, remove the
hard disk drive from the package.
Attention:
Do not press on the top of the drive. Pressing the top might
damage the drive.
2. Align the drive with the guide rails in the drive bay.
3. Pull the loops of the drive toward each other; then, carefully slide the drive into
the bay until it stops, and release the loops.
Note:
Do not release the loops on the drive until it is completely seated.
4. Install the filler panel in the drive bay.
5. Turn on the system-board tray (see “Turning on the system-board tray” on page
Removing the PCIe adapter bay cover
To remove the adapter bay cover from the I/O enclosure, complete the following
steps.
Screws
Slot cover
PCIe bay cover
I/O enclosure
PCI slots
Tabs
Adapter
End of
Bay cover
1. Read the safety information that begins on page vii and “Installation guidelines”
2. If the system-board tray is installed in a chassis, remove it (see “Removing the
system-board tray from a 2U chassis” on page 126).
3. Remove the I/O enclosure (see “Removing an expansion enclosure from a
system-board tray” on page 131).
4. Carefully set the I/O enclosure on a flat, static-protective surface.
5. Remove the two screws that secure the PCIe adapter bay cover to the I/O
enclosure and save the screws for future use.
6. Slide the PCIe adapter bay cover out of the mounting tabs and remove it from
the I/O enclosure.
7. If you are instructed to return the PCIe adapter bay cover, follow all packaging
instructions, and use any packaging materials for shipping that are supplied to
you.
Installing the PCIe adapter bay cover
To install the PCIe adapter bay cover on the I/O enclosure, complete the following
steps.
Chapter 5. Removing and replacing server components
143
Содержание System x iDataPlex dx360 M2
Страница 2: ......
Страница 16: ...xiv System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 138: ...122 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 256: ...240 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 262: ...246 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 263: ......
Страница 264: ...Part Number 00D3199 Printed in USA 1P P N 00D3199...