Table 3. Integrated management module error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 4, “Parts listing,” on page 109 to determine which components are customer replaceable
units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Message
Severity
Description
Action
Memory uncorrectable error
detected for DIMM All
DIMMs on Memory
Subsystem All DIMMs.
Error
A memory uncorrectable error has
occurred.
1. Check the IBM support website
for an applicable retain tip or
firmware update that applies to
this memory error.
2. Manually re-enable all affected
DIMMs if the server firmware
version is older than UEFI
v1.10. If the server firmware
version is UEFI v1.10 or newer,
disconnect and reconnect the
server to the power source and
restart the server.
3. Swap the affected DIMMs (as
indicated by the error LEDs on
the system board or the event
logs) to a different memory
channel or microprocessor (see
“Installing a memory module” on
page 164).
4. If the problem follows the
DIMM, replace the failing DIMM
(see “Removing a memory
module” on page 163 and
“Installing a memory module” on
page 164).
(Continued on the next page)
90
System x iDataPlex dx360 M2: Problem Determination and Service Guide
Содержание System x iDataPlex dx360 M2
Страница 2: ......
Страница 16: ...xiv System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 138: ...122 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 256: ...240 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 262: ...246 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 263: ......
Страница 264: ...Part Number 00D3199 Printed in USA 1P P N 00D3199...