Power problems
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 4, “Parts listing,” on page 109 to determine which components are customer replaceable
units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom
Action
The power-control button does
not work (the system-board tray
does not start).
1. Make sure that the operator panel power-control button is working correctly:
a. Disconnect the chassis power cord.
b. Reconnect the power cord.
c. Press the power-control button.
2. Make sure that:
v
The power cord is fully seated in the power-supply inlet and connected to a
working electrical outlet and that the power-supply fan is working.
v
The system-board tray contains the correct type of DIMMs.
v
The DIMMs are correctly seated.
v
The microprocessor is correctly installed.
3. Reseat the following components:
a. DIMMs
b. Power-supply cables to all internal components
c. Power supply
4. Replace the following components one at a time, in the order shown, restarting
the system-board tray each time:
a. DIMMs
b. Power supply
5. If you just installed an optional device, remove it, and restart the system-board
tray. If the system-board tray now starts, you might have installed more devices
than the power supply supports.
6. See “Solving undetermined problems” on page 106.
The system-board tray does not
turn off.
1. Determine whether you are using an Advanced Configuration and Power
Interface (ACPI) or a non-ACPI operating system. If you are using a non-ACPI
operating system, complete the following steps:
a. Press Ctrl+Alt+Delete.
b. Turn off the system-board tray by holding the power-control button for 5
seconds.
c. Restart the system-board tray.
d. If the system-board tray fails POST and the power-control button does not
work, disconnect the ac power cord for 20 seconds; then, reconnect the ac
power cord and restart the system-board tray.
2. (Trained service technician only) If the problem remains or if you are using an
ACPI-aware operating system, suspect the system board.
The system-board tray
unexpectedly shuts down, and
the LEDs on the operator panel
are not lit.
See “Solving undetermined problems” on page 106.
Chapter 3. Diagnostics
37
Содержание System x iDataPlex dx360 M2
Страница 2: ......
Страница 16: ...xiv System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 138: ...122 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 256: ...240 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 262: ...246 System x iDataPlex dx360 M2 Problem Determination and Service Guide...
Страница 263: ......
Страница 264: ...Part Number 00D3199 Printed in USA 1P P N 00D3199...