Installing the 3U chassis top cover
To install the 3U chassis top cover, complete the following steps.
1. Make sure that no wires are protruding and might interfere with the cover.
2. Orient the cover over the rear of the chassis so that the retention tabs on the
cover align with the tabs in the chassis.
3. Slide the cover onto the chassis until the cover-release buttons click into place.
4. Install the chassis in the iDataPlex rack (see “Installing a 3U chassis in a Type
7825 iDataPlex rack” on page 191).
Removing the battery
To remove the battery, complete the following steps.
1. Read the safety information that begins on page vii and “Installation guidelines”
2. If the system-board tray is installed in a chassis, remove it (see “Removing the
system-board tray from a 2U chassis” on page 126 or “Removing the
system-board tray from a 3U chassis” on page 128).
Chapter 5. Removing and replacing server components
137