1.
2.
-
-
-
1.
2.
-
-
1.
2.
-
-
1.
2.
-
Create 1 instance of function block
AXIS_REF_DDS
(located in folder
DDS_Drive
) for every servo drive that has to be control-
led or monitored.
To create a link to the physical servo drive, link each instance of
AXIS_REF_DDS
to 1 physical servo drive. This makes it the
logical representation of 1 physical servo drive.
Open the
Logical View
.
Initialize each instance with its node number and the slot name it is connected to (for example, IF3).
Initialize each instance of a drive with its
DriveType
.
Example
Illustration 57: Instantiation of AXIS_REF_DDS and Setting of Initial Values
6.10.6 Instantiating PSM_REF in Automation Studio™
Procedure
Create 1 instance of function block
PSM_REF
(located in folder
DDS_PSM
) for every Power Supply Module (PSM) that has to
be controlled or monitored.
To create a link to the physical PSM, link each instance of
PSM_REF
to 1 physical PSM. This makes it the logical representa-
tion of 1 physical PSM.
Open the
Logical View
.
Initialize each instance with its node number and the slot name it is connected to (for example, IF3).
6.10.7 Instantiating DAM_REF in Automation Studio™
Procedure
Create 1 instance of function block
DAM_REF
(located in folder
DDS_DAM
) for every Decentral Access Module (DAM) that
has to be controlled or monitored.
To create a link to the physical DAM, link each instance of
DAM_REF
to 1 physical DAM. This makes it the logical representa-
tion of 1 physical DAM.
Open the
Logical View
.
Initialize each instance with its node number and the slot name it is connected to (for example, IF3).
6.10.8 Instantiating ACM_REF in Automation Studio™
Procedure
Create 1 instance of function block
ACM_REF
(located in folder
DDS_ACM
) for every Auxiliary Capacitors Module (ACM) that
has to be controlled or monitored.
To create a link to the physical ACM, link each instance of
ACM_REF
to 1 physical ACM. This makes it the logical representa-
tion of 1 physical ACM.
Open the
Logical View
.
AQ262449648484en-000101 / 175R1135
90 | Danfoss A/S © 2020.08
Commissioning
VLT® Servo Drive System ISD 510/DSD 510
Operating Guide