background image

SUPRA Mains Driver Integrated System

BEFORE YOU START

SUPPLIED PARTS

www.Lumishore.com

45-0079-Rev 5

Lumishore UK Unit 2, Technium 1, Kings Road, Swansea, SA1 8PH, UK  |  +44(0)208 144 1694  |  [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34243  |  (941) 405-3302  |  [email protected]

SUPRA Driver Installation and Operating Instructions

(Note: SUPRA Driver for use with SY 225, SY 250, SY 300,

SY310 and TRX 802 Lights)

•    

High Intensity LED light – Do not stare into the LED module at close proximity.

•   Always ensure that the vessel’s power source is disconnected or isolated prior to installation
•   A qualified professional should carry out both the electrical and mechanical installation. If in doubt please contact LUMISHORE.
    refer to product support section
•   The Driver supplies voltage and current to the Underwater lights. 

Under no circumstances should the light cable be cut and

     connected directly to voltage

•   Always use a suitable fuse or circuit breaker to protect the complete system. Each light to be individually fused.
•   The light should be installed 6” - 10” (150-250mm) below the minimum load waterline.
•   For best results install the lights between 2.5ft (0.8m) and 6.5ft (2m) apart.
•   Never try to install or remove light with the vessel in the water.
•   Lights should not be exposed to any temperatures in excess of 150°F (65°C). For example, next to hot engine components or
    where exhaust emissions could be expelled onto the light while underwater

1

Congratulations! You have purchased a LUMISHORE advanced technology underwater light. Every care has been taken 

to ensure your LUMISHORE lights and drivers arrives in perfect condition, so please enjoy the ultimate experience in 

underwater lighting.

LUMISHORE high intensity underwater lights are designed for those owners who prefer the integrity of a Weld-in instal-

lation in a light that employs the most powerful, efficient and cost effective underwater LED lighting on the market 

today. The LUMISHORE Weld-in lighting system is suitable for many sizes and types of watercraft, including Sports 

Boats, Cruisers, Yachts and Super Yachts. LUMISHORE Weld-in LED lights come with a compact electronic driver module 

to ensure trouble free operation for years to come.

Please read the following pages before attempting installation to ensure complete understanding of the 

LUMISHORE LED lights.

Product

 

No

 

SY250

 

39-0167

 

SY 300 / 310

 

39-0168

SY225

 

39-0292

 

TRX 802

 

39-0170

 

SUPRA Mains Driver Part Numbers

Summary of Contents for SUPRA SY225

Page 1: ...esults install the lights between 2 5ft 0 8m and 6 5ft 2m apart Never try to install or remove light with the vessel in the water Lights should not be exposed to any temperatures in excess of 150 F 65 C For example next to hot engine components or where exhaust emissions could be expelled onto the light while underwater 1 Congratulations You have purchased a LUMISHORE advanced technology underwate...

Page 2: ...er can be configured to give any combination of the following modes of operation See page 4 in this manual for instructions on how to connect the drivers to give the required functions Note These instructions cover SUPRA White Blue SUPRA Cold White Warm White depending on which are being installed Solid White Cold White Solid Blue Warm White Solid White Cold White or Solid Blue Warm White Selectab...

Page 3: ...r end The input voltage cable used should be a suitable marine approved mains cable For details on the light installation please refer to the light installation instructions Input Voltage Range 90 240VAC 50 60Hz Maximum Input Current 2 1Amp Input Wiring Brown Wire LIVE Blue Wire NEUTRAL Green Yellow EARTH Function Port Light Port www Lumishore com Lumishore UK Unit 2 Technium 1 Kings Road Swansea ...

Page 4: ...d by a connector Function Port Light Port 2 1 7 6 5 4 8 3 WHITE COLD WHITE ONLY 2 and 8 5 and 6 2 1 7 6 5 4 8 3 BLUE WARM WHITE ONLY 3 and 8 5 and 6 Move Jumper Positions HOW TO FIT A SWITCH FOR WHITE COLD WHITE AND BLUE WARM WHITE SELECTION Using the optional Switch Assembly 39 0146 and the supplied Y Splitter Cable 24 0208 The Supra Mains driver can be configured to work with an external switch ...

Page 5: ...L U E G R E E N Y E L LO W LED STATUS x3 LIGHT TEMP x5 NO LIGHT BLINK ATRB OK Label PN 21 0214 REV A Model No HLG 185H 42B AC DC INTELLIGENT COMBI DRIVER S E LV IP67 T Ü V R he inla nd P roduc t S a fe ty B AU A R T G E P R Ü F T T Y P E A P P R OV E D 90 C 60 C t t c a LIGHT CNCT DIM CNCT LUMISHORE PRODUCT CODE CONFIGURED FOR MADE IN CHINA 90w XX XXXX I N P U T 90 305V A C 2 1 A 47 63Hz A C L B R...

Page 6: ... 12volts 12 V DC Signal Generator Note In this mode when the lights are initially switched ON they will light up and wait for a signal Once they receive this signal they will respond NO signal OFF Signal ON This will remain the case until the lights are switched off and on again using the switch 1 10v Dimming Input The Lights can be dimmed using a 3rd party 1 10volt dimming module Connect the 1 10...

Page 7: ...nqualified personnel unauthorized repair or modification will void this warranty For the avoidance of confusion and doubt non compliance with all installation maintenance and operating instructions in this document constitute non conformance with warranty terms Full warranty details are available at www lumishore com TESTING THE LIGHTS The underwater lighting system should always be tested before ...

Reviews: