Pins
(left to
right)
Descrip-
tion
Note
Rating/parameter
7
24/48 V
–
1
The maximum current rating for 1 pair of EXM is 62 A. In systems with 2 PSM 510 modules, 2 pairs of EXM 510 modules can be used to achieve a
maximum current rating of 124 A.
11.9.13.1 Cable Cross Sections for EXM 510
Table 152: Minimum Cable Cross Sections for EXM 510 Cables
Cable
CE
UL
DC+/DC–
16 mm
2
(minimum 70 °C, Cu)
6 AWG (minimum 75 °C, Cu)
24 V, functional PE
16 mm
2
(minimum 70 °C, Cu)
6 AWG (minimum 90 °C, Cu)
(1)
1
Minimum 75 °C is allowed if less than 45 A are measured on the cable.
11.10 General Specifications and Environmental Data
11.10.1 ISD 510/DSD 510 Servo Drive
Table 153: General Specifications and Environmental Conditions for ISD 510/DSD 510
Specification
Value
Vibration test
Random vibration: 7.54 g (2h/axis according to EN 60068-2-64)
Sinusoidal vibration:0.7 g (2h/axis according to EN 60068-2-6)
Maximum relative humidity
Storage/transport: 5–93% (non-condensing)
Stationary use: 15–85% (non-condensing)
Ambient temperature
Operating: 5–40 °C nominal, up to 55 °C with derating
Transport: –25 to +70 °C
Storage: –25 to +55 °C
Installation altitude
No limitation up to 1000 m above sea level.
Maximum 2000 m above sea level with derating.
9% derating up to 2000 m with normal supply voltage, 3-phase AC 400 V.
EMC standard for emission and immunity EN 61800-3
EMC immunity functional safety
EN 61800-5-2 Annex E
Pollution degree
2
Overvoltage category
III
IP ratings
See
11.11.1 Protection Ratings for ISD 510 Servo Drive
and
AQ262449648484en-000101 / 175R1135
214 | Danfoss A/S © 2020.08
Specifications
VLT® Servo Drive System ISD 510/DSD 510
Operating Guide