6.11 Programming with TwinCAT®
6.11.1 Requirements for Programming with TwinCAT®
To integrate the ISD 510/DSD 510 servo drives and the PSM 510, DAM 510, or ACM 510 into a TwinCAT
®
project, the following files
are required:
Library for the ISD 510 servo system:
Danfoss_VLT_ServoMotion_V_x_y_z.lib
ESI file (EtherCAT
®
Slave Information) for the standard ISD 510 servo drive: Danfoss_ISD510_S.xml
ESI file (EtherCAT
®
Slave Information) for the advanced ISD 510 servo drive: Danfoss_ISD510_A.xml
ESI file (EtherCAT
®
Slave Information) for the standard DSD 510 servo drive: Danfoss_DSD510_S.xml
ESI file (EtherCAT
®
Slave Information) for the advanced DSD 510 servo drive: Danfoss_DSD510_A.xml
ESI file (EtherCAT
®
Slave Information) for the Power Supply Module: Danfoss_PSM510.xml
ESI file (EtherCAT
®
Slave Information) for the Decentral Access Module: Danfoss_DAM510.xml
ESI file (EtherCAT
®
Slave Information) for the Auxiliary Capacitor Module: Danfoss_ACM510.xml
6.11.2 Creating a TwinCAT® Project
Information on how to install TwinCAT
®
can be found in detail in the Beckhoff Information System (
Open the information system and select [TwinCAT 2
→
TwinCAT Quick Start
→
Installation].
Information on how to create a project in TwinCAT
®
can be found in detail in the Beckhoff Information System (
). Open the information system and select [TwinCAT 2
→
TwinCAT Quick Start or TwinCAT 2
→
TX1200 TwinCAT
PLC
→
TwinCAT PLC Control].
6.11.3 Including the TwinCAT® Library into a TwinCAT® Project
Procedure
In the
Resources
tab of TwinCAT
®
PLC Control, open the
Library Manager
.
In the upper left area of the
Library Manager
window, right-click and select
Additional Library...
.
Select the Danfoss_VLT_ServoMotion_V_x_y_z file (according to the location on the hard drive).
Click on
Open
. Now the libraries are integrated into the TwinCAT
®
PLC control project.
e3
0b
h6
11
.1
0
Illustration 66: Library Manager after Including the ServoMotion Library
Inside the library, the POUs are organized into folders:
DDS_Drive
Contains program organization units (POUs) defined by PLCopen
®
(name starting with MC_) and POUs defined by
Danfoss (name starting with DD_). The Danfoss POUs provide additional functionality for the axis.
It is possible to combine POUs defined by PLCopen
®
with POUs defined by Danfoss.