1.
2.
3.
4.
5.
1.
2.
3.
-
-
4.
-
-
-
-
N O T I C E
Do not remove or rename these libraries.
Procedure
Extract the files from the
Danfoss_VLT_ServoMotion_V_x_y_z.zip
file (according to the location on the hard drive).
The
DDS_Xxxx.xml
file and
XML_DDS_Xxxx
folder must be located together in the same folder to import the library.
In the
Project
tab, right-click on
LIBRARIES
and select [Export/import
→
Import folders/objects].
e
3
0
b
g
3
5
8
.1
0
Illustration 76: Import Library
Select file
DDS_Intern.xml
according to the location on the hard drive.
Click on
OK
. Now the library is integrated into the SIMOTION SCOUT
®
project.
Repeat steps 2–4 for
DDS_BasCam.xml
,
DDS_Drive.xml
,
DDS_LabCam.xml
,
DDS_PSM.xml
,
DDS_DAM.xml
, and
DDS_ACM.xml
.
6.13.5 Importing Devices into SIMOTION SCOUT®
N O T I C E
For each physical servo drive, PSM 510, DAM 510, or ACM 510, add 1 entry to the PROFINET
®
Ethernet network in the
HW
Config
tool.
Procedure
Open the
HW Config
tool.
Select [Options
→
Install GSD File...].
To add a servo drive, select the xml file (according to the location on the hard drive) and click on
Install
. In the filename,
2.xx
represents the version number and
yyyymmdd
represents the date.
GSDML-V2.xx-Danfoss-ISD-yyyymmdd.xml
GSDML-V2.xx-Danfoss-DSD-yyyymmdd.xml
Repeat steps 2 and 3 for:
Power Supply Module (PSM 510):
GSDML-V2.xx-Danfoss-PSM-yyyymmdd.xml
Decentral Access Module (DAM 510):
AQ262449648484en-000101 / 175R1135 | 109
Danfoss A/S © 2020.08
Commissioning
VLT® Servo Drive System ISD 510/DSD 510
Operating Guide