9.3.53 Homing error on entering homing mode (0x8693 / 0x10F)
This error is valid for ISD 510/DSD 510.
Table 93: Homing error on entering homing mode (0x8693 / 0x10F)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x8693 0x10F
Homing error on enter-
ing homing mode
Warning
Could not enter homing mode
(for example velocity not 0).
Homing mode
fail
9.3.54 Homing error on start homing method (0x8694 / 0x110)
This error is valid for ISD 510/DSD 510.
Table 94: Homing error on start homing method (0x8694 / 0x110)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x8694 0x110
Homing error on start
homing method
Warning
Could not start homing method
(for example drive not in stand-
still).
Homing meth-
od fail
9.3.55 Homing error distance (0x8695 / 0x111)
This error is valid for ISD 510/DSD 510.
Table 95: Homing error distance (0x8695 / 0x111)
Code
PROFINET
®
code Name
Severity (warning/error/trip
lock)
Description
LCP name
0x8695 0x111
Homing error dis-
tance
Warning
Homing distance
reached.
Homing distance
9.3.56 Mechanical brake failure (0xFF01 / 0x112)
This error is valid for ISD 510/DSD 510.
Table 96: Mechanical brake failure (0xFF01 / 0x112)
Code
PROFINET
®
code Name
Severity (warning/error/trip
lock)
Description
LCP name
0xFF01 0x112
Mechanical brake
failure
Trip lock
No brake or wire failure. brake mech fail
9.3.57 Short circuit in mechanical brake control (0xFF02 / 0x113)
This error is valid for ISD 510/DSD 510.
Table 97: Short circuit in mechanical brake control (0xFF02 / 0x113)
Code
PROFINET
®
code Name
Severity (warning/error/
trip lock)
Description
LCP name
0xFF02 0x113
Short circuit in mechani-
cal brake control
Trip lock
Short circuit in brake
control.
brake mech
short
9.3.58 External interface power failure (0xFF0A / 0x114)
This error is valid for ISD 510/DSD 510.
AQ262449648484en-000101 / 175R1135 | 171
Danfoss A/S © 2020.08
Diagnostics
VLT® Servo Drive System ISD 510/DSD 510
Operating Guide