1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
1.
2.
3.
a.
b.
4.
1
Ethernet connector IN (X1 IN)
2
Ethernet connector OUT (X2 OUT)
3
24/48 V IN connector (INPUT 24/48 V)
4
STO connector IN (STO PSM)
5
STO connector OUT (STO PSM)
6
I/O connector (I/O PSM)
7
Relay connector (REL PSM)
Procedure
Connect the Ethernet cable from the PLC to the Ethernet input connector (X1 IN) [1].
Connect the Ethernet cable from the Ethernet output connector (X2 OUT) [2] to the next module.
Insert the wires into the 24/48 V IN (INPUT 24/48 V) connector.
Insert the 24/48 V IN connector [3].
Insert the wires into the STO connector IN (STO PSM) connector.
Insert the STO connector IN connector [4].
Insert the wires into the STO connector OUT (STO PSM) connector.
Insert the STO connector OUT connector [5].
If I/Os are required, insert the wires into the I/O connector and insert the connector (I/O PSM) [6].
If a relay is required, insert the wires into the relay connector and insert the connector (REL PSM) [7].
5.10.2.2 Connecting the Cables on the Bottom of the Power Supply Module PSM 510
2
1
3
4
e3
0b
g4
66
.1
0
Illustration 46: Connectors on the Bottom of PSM 510
1
Holder for internal brake resistor connector when
not in use
2
AC mains supply connector
3
PE screws
4
Internal/external brake resistor connector
Procedure
Insert the wires into the AC mains supply connector.
Insert the AC mains supply connector [2].
If an external brake resistor is required:
Unplug the internal brake resistor connector [4] and insert the external brake connector in its place.
Plug the internal brake resistor connector to the internal brake connector holder [1].
Connect the PSM 510 to PE using one of the PE screws on the front side [3] and a PE wire. The tightening torque is 3 Nm.
AQ262449648484en-000101 / 175R1135
76 | Danfoss A/S © 2020.08
Electrical Installation
VLT® Servo Drive System ISD 510/DSD 510
Operating Guide