9.3.28 UAUX charging error (0x3297 / 0x154)
This error is valid for DAM 510.
Table 68: UAUX charging error (0x3297 / 0x154)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x3297 0x154
U
AUX
charging
error
Error
Load error when U
AUX
is charging. The maxi-
mum time limit to charge the AUX line has
been exceeded.
UAUX charg
err
9.3.29 DC link shutdown error (0x3298 / 0x165)
This error is valid for DAM 510.
Table 69: DC link shutdown error (0x3298 / 0x165)
Code
PROFINET
®
code Name
Severity (warning/error/
trip lock)
Description
LCP name
0x3298 0x165
DC link shutdown
error
Error
Error when UDC is in shut-
down phase.
UDC shutdwn err
9.3.30 UAUX shutdown error (0x3299 / 0x155)
This error is valid for DAM 510.
Table 70: UAUX shutdown error (0x3299 / 0x155)
Code
PROFINET
®
code Name
Severity (warning/error/
trip lock)
Description
LCP name
0x3299 0x155
U
AUX
shutdown
error
Error
Error when U
AUX
is in shut-
down phase.
UAUX shtdwn
err
9.3.31 UAUX undervoltage hardware (0x329A / 0x156)
This error is valid for PSM 510, DAM 510, and ACM 510.
Table 71: UAUX undervoltage hardware (0x329A / 0x156)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x329A 0x156
U
AUX
undervoltage
hardware
Error
U
AUX
undervoltage detected by
hardware circuit.
AUX undervol
HW
9.3.32 Device overtemperature (0x4210 / 0x157)
This error is valid for PSM 510, DAM 510, and ACM 510.
Table 72: Device overtemperature (0x4210 / 0x157)
Code
PROFINET
®
code
Name
Severity (warn-
ing/error/trip
lock)
Description
LCP name
0x4210 0x157
Device over-
temperature
Warning, error
Triggered when the maximum temperature of the
main device component is exceeded.
PSM: Thyristor rectifier module.
DAM: Maximum temperature of both high side and
low side IGBTs.
overtemp
device
AQ262449648484en-000101 / 175R1135
166 | Danfoss A/S © 2020.08
Diagnostics
VLT® Servo Drive System ISD 510/DSD 510