11.9.2 Brake Connectors
Brake connectors are located on the Power Supply Module (PSM 510).
11.9.2.1 Brake Resistor Connector on PSM 510
e
3
0
b
g
4
5
0
.1
0
Illustration 142: Brake Connector on PSM 510
Table 135: Pin Assignment of Brake Connector on PSM 510
Pins (left to
right)
Description Notes
Ratings
1
DC+/R+
Used for connecting a brake re-
sistor.
Nominal voltage: 560–800 V DC
Maximum brake current: 80 A
Conductor cross-section range: 0.75–16 mm
2
(AWG 18–AWG 4)
2
R–
N O T I C E
The maximum length of the brake cable is 30 m (shielded).
11.9.3 Ethernet Connectors
Ethernet connectors are located on all the system modules.
e
3
0
b
e
3
9
5
.1
0
8
1
Illustration 143: Ethernet Connector
N O T I C E
Only PELV potential can be connected to the digital inputs and outputs.
11.9.3.1 Ethernet Connectors on PSM 510 and ACM 510
Table 136: Ethernet Connectors on PSM 510 and ACM 510
Connector name
Description
Pins
Ratings
X1 IN
Ethernet IN
1: TX+
2: TX–
3: RX+
4: –
5: –
6: RX–
7: –
8: –
According to standard 100BASE-T.
X2 OUT
Ethernet OUT1
AQ262449648484en-000101 / 175R1135
204 | Danfoss A/S © 2020.08
Specifications
VLT® Servo Drive System ISD 510/DSD 510
Operating Guide