Possible Causes
Fan is not mounted.
Fan is blocked.
Troubleshooting
Check if the fan is blocked.
Check the fan cables for proper connection or damage.
9.3 Error Codes for ISD 510/DSD 510 Servo System
9.3.1 No error (0x0000 / 0x0)
This error code is valid for PSM 510, DAM 510, ACM 510, and ISD 510/DSD 510.
Table 41: No error (0x0000 / 0x0)
Code
PROFINET
®
code
Name
Severity (warning/error/trip lock)
Description
LCP name
0x0000
0x0
No error
Error
No error.
–
9.3.2 Generic application error (0x1000 / 0x100)
This error is valid for PSM 510, DAM 510, ACM 510, and ISD 510/DSD 510.
Table 42: Generic err (0x1000 / 0x100)
Code
PROFINET
®
code Name
Severity (warning/error/trip
lock)
Description
LCP name
0x1000 0x100
Generic application error Error
Generic application error. generic err
9.3.3 Overcurrent Trip (0x2310 / 0x101)
This error is valid for ISD 510/DSD 510.
Table 43: Overcurr out (0x2310 / 0x101)
Code
PROFINET
®
code Name
Severity (warning/error/trip lock)
Description
LCP name
0x2310 0x101
Overcurrent trip Error
Overcurrent trip on output.
overcurr trip
9.3.4 High cont. current overload (0x2311 / 0x15F)
This error is valid for DAM 510 and ISD 510/DSD 510.
Table 44: High current overload (0x2311 / 0x15F)
Code
PROFINET
®
code Name
Severity (warning/error/
trip lock)
Description
LCP name
0x2311 0x15F
High cont. current
overload
Error
High continuous current over-
load error.
High curr ovld
9.3.5 Continuous current overload (0x2312 / 0x160)
This error is valid for DAM 510 and ISD 510/DSD 510.
Table 45: Continuous current overload (0x2312 / 0x160)
Code
PROFINET
®
code Name
Severity (warning/error/
trip lock)
Description
LCP name
0x2312 0x160
Continuous current
overload
Error
Continuous current over-
load error.
cont curr ovld
AQ262449648484en-000101 / 175R1135 | 161
Danfoss A/S © 2020.08
Diagnostics
VLT® Servo Drive System ISD 510/DSD 510
Operating Guide