86
Commander SE Advanced User Guide
Issue Number: 4
Indicates the version of drive software fitted
If any number other than 0 is programmed in this parameter a user security will be applied. When a user security code has
been programmed, none of the parameters in the basic parameter set can be altered.
This parameter indicates the drives continuous current rating in amps.
This parameter indicates the voltage rating of the drive.
Indicates the sub-version of drive software fitted.
Indicates the version of DSP software fitted.
Sets the timeout in seconds for the drive display to revert to status mode from parameter mode following no action on the
keypad.
11.27~
11.28
Unused parameters
11.29
Drive software version
Ú
1.00 ~ 9.99
Ö
RO
Uni
P
11.30
User security code
Ú
0 ~ 9999
Ö
0
RW
Uni
S
P
11.31
Unused parameter
11.32
Drive rated continuous current
Ú
1.50 ~ 70.00
Ö
A
RO
Uni
P
11.33
Drive voltage rating
Ú
240 ~ 480
Ö
V
RO
Uni
P
11.34
Drive software sub version
Ú
0 ~ 99
Ö
RO
Uni
P
11.35
Drive DSP software version
Ú
0 ~ 9.9
Ö
RO
Uni
P
11.36~
11.40
Unused parameters
11.41
Status mode timeout
Ú
0 ~ 250
Ö
240
s
RW
Uni
P
Содержание COMMANDER SE
Страница 76: ...76 Commander SE Advanced User Guide Issue Number 4...
Страница 93: ...Commander SE Advanced User Guide 93 Issue Number 4...
Страница 98: ...98 Commander SE Advanced User Guide Issue Number 4...
Страница 142: ...142 Commander SE Advanced User Guide Issue Number 4 Figure 6 9 Input line reactor 4400 0241 All dimensions in mm...
Страница 144: ...144 Commander SE Advanced User Guide Issue Number 4 Figure 7 3 Commander SE Size 4 All dimensions in mm...