Commander SE Advanced User Guide
187
Issue Number: 4
12.25 Quickey Compatibility
Due to different versions of Drive user interface software, it is possible to get a compatibility issue when using the Quickey to
clone parameter set-ups between drives. This compatibility issue will cause the drive to trip on C.dat.
The following table gives the compatibility between different versions of drive user interface software:
NO
:
The Quickey cannot clone between these two versions of drive software
YES
: The Quickey can clone between these two versions of drive software
*V02.00.04 is only used on Commander SE Size 5.
12.26 Controlling the Commander SE via the Universal Keypad
Example 1
This set up uses the UP and DOWN buttons on the Universal Keypad to control the speed of the motor: UP to increase the
speed and DOWN to decrease the speed.
The Enable/Stop/Start/Forward/Reverse control is from the drives terminals and not the Universal Keypad buttons.
Keypad top line display set up
Keypad bottom line display set up
Keypad buttons set up
Drive parameters set up
Perform a save routine:
xx.00
= 1000 and press the red Stop / Reset button on the drive.
Perform a Universal Keypad save routine:
99.00
= 1000 and press the red Stop / Reset button on the keypad.
Software
V01.02.01 V01.03.00 V01.05.00 V01.07.00 V01.08.00 V01.09.01 V01.10.00 V02.00.01 V02.00.04*
V01.02.01
NO
NO
NO
NO
NO
NO
NO
NO
V01.03.00
NO
YES
NO
NO
NO
NO
NO
NO
V01.05.00
NO
YES
NO
NO
NO
NO
NO
NO
V01.07.00
NO
NO
NO
YES
YES
YES
YES
YES
V01.08.00
NO
NO
NO
YES
YES
YES
YES
YES
V01.09.01
NO
NO
NO
YES
YES
YES
YES
YES
V01.10.00
NO
NO
NO
YES
YES
YES
YES
YES
V02.00.01
NO
NO
NO
YES
YES
YES
YES
YES
V02.00.04*
NO
NO
NO
YES
YES
YES
YES
YES
Parameter
Description
Value
99.16
HMI 2 source address
11
99.17
HMI 2 source parameter
1.21
99.20
HMI 2 text
Speed reference
99.41
HMI 2 increment
100
99.42
HMI 2 upper limit
50,000
99.43
HMI 2 lower limit
0
Parameter
Description
Value
99.09
HMI 1 source address
11
99.10
HMI 1 source parameter
4.01
99.13
HMI 1 text
Motor I
Parameter
Description
Value
99.05
Keypad control buttons
Disable
Parameter
Description
Value
00.05
Speed reference selector
Pr
6.43
Control word enable
0
Содержание COMMANDER SE
Страница 76: ...76 Commander SE Advanced User Guide Issue Number 4...
Страница 93: ...Commander SE Advanced User Guide 93 Issue Number 4...
Страница 98: ...98 Commander SE Advanced User Guide Issue Number 4...
Страница 142: ...142 Commander SE Advanced User Guide Issue Number 4 Figure 6 9 Input line reactor 4400 0241 All dimensions in mm...
Страница 144: ...144 Commander SE Advanced User Guide Issue Number 4 Figure 7 3 Commander SE Size 4 All dimensions in mm...