102
Commander SE Advanced User Guide
Issue Number: 4
3.15 Menu 21: Second motor map
Parameter
Range
Type
Default
Setting
Update Rate
21.01 Motor 2 maximum speed clamp
0 ~ 1000.0 Hz
RW
Uni
EUR> 50.0
USA> 60.0
B
21.02 Motor 2 minimum speed clamp
0 ~ P21.01 Hz
RW
Uni
0.0
B
21.03
Motor 2 speed reference
selector
(0) A1.A2
(1) A1.Pr
(2) A2.Pr
(3) Pr
(4) Pad
(5) Prc
RW
Txt
EUR> (0)A1.A2
USA> (4)Pad
L2
21.04 Motor 2 Acceleration ramp rate
0.0 ~ 3200.0
s/100Hz
RW
Uni
5.0 L2
21.05 Motor 2 Deceleration ramp rate
0.0 ~ 3200.0
s/100Hz
RW
Uni
10.0 L2
21.06 Motor 2 rated frequency
1000.0 Hz
RW
Uni
EUR> 50.0
USA> 60.0
BS, MC
21.07 Motor 2 motor rated current
0 ~ Drive rating
RW
Uni
Drive rating
BS, MC
21.08
Motor 2 motor rated full load
rpm
0 ~ 9999rpm
RW
Uni
EUR> 1500
USA> 1800
BS, MC
21.09 Motor 2 motor rated voltage
400V unit =
0 ~ 480V
200V unit =
0 ~ 240V
RW
Uni
EUR>
400V unit =400V
200V unit =230V
USA>
400V unit =460V
200V unit =230V
BF, MC
21.10 Motor 2 rated power factor
0 ~ 1.00
RW
Uni
0.85
BS, MC
21.11 Motor 2 number of poles
Auto
2P ~ 8P(0-4)
RW
Uni
Txt
Auto (0)
BS, MC
21.12 Motor 2 stator resistance
0 ~ 99.99
Ω
RW
Uni
P
0.0 BS,
MC
21.13 Motor 2 voltage offset
0 ~ 25.5V
RW
Uni
P
BF, MC
21.14 Motor 2 leakage inductance
000.0 ~ 500.0mH
RO
Uni
P
A
21.15 Motor map 2 active
0 ~ 1
RO
Bit
P
0
B
Содержание COMMANDER SE
Страница 76: ...76 Commander SE Advanced User Guide Issue Number 4...
Страница 93: ...Commander SE Advanced User Guide 93 Issue Number 4...
Страница 98: ...98 Commander SE Advanced User Guide Issue Number 4...
Страница 142: ...142 Commander SE Advanced User Guide Issue Number 4 Figure 6 9 Input line reactor 4400 0241 All dimensions in mm...
Страница 144: ...144 Commander SE Advanced User Guide Issue Number 4 Figure 7 3 Commander SE Size 4 All dimensions in mm...