Commander SE Advanced User Guide
17
Issue Number: 4
3 Menus
The following table gives a list of level 1 and level 2 parameters and their corresponding extended menu parameter(s).
* Only becomes active when parameter 29 is set to “br.Eu” or “br.US” and the STOP/RESET button is pressed for 1 second.
Par
Description
Default
Corresponding
extended menu
parameter
Level 1 and 2
setting
Update
rate
EUR
USA
LEVEL 1
01
Min. speed (Hz)
0.0
1.07
B
02
Max. speed (Hz)
50.0
60.0
1.06
B
03
Accel. rate (s/100Hz)
5.0
2.11
L2
04
Decel. rate (s/100Hz)
10.0
2.21
L2
05
Ref. select
A1.A2
PAd
1.14
L2
06
Motor rated current (A)
Drive rating
5.07
BS, MC
07
Motor rated speed (rpm)
1500
1800
5.08
BS, MC
08
Motor rated voltage (V)
230 / 400
230 / 460
5.09
BF, MC
09
Motor power factor
0.85
5.10
BF, MC
10
Parameter access
L1
L1
11.44
B
LEVEL 2
11
Preset 1 (Hz)
0.0
1.21
L2
12
Preset 2 (Hz)
0.0
1.22
L2
13
Preset 3 (Hz)
0.0
1.23
L2
14
Preset 4 (Hz)
0.0
1.24
L2
15
Jog. speed (Hz)
1.5
1.05
L2
16
Current mode (mA)
4-.20
7.11
L2
17
Enable negative preset speeds
OFF
1.10
B
18
Last trip
--
10.20
B
19
Trip before parameter 18
--
10.21
B
20
Trip before parameter 19
--
10.22
B
21
Trip before parameter 20
--
10.23
B
22
Load display units
Ld
4.21
B
23
Speed display units
Fr
5.34
B
24
Customer scaling
1.00
11.21
B
25
Security setup
0
11.30
B
26
Fwd/rev key enable
OFF
6.13
L1
27
Power up key. ref
0
1.51
I
28
Parameter cloning
no
11.42
B
29
Load defaults
no
11.43
B
30
Ramp mode
1
2.04
B
31
Stopping mode
1
6.01
L1
32
Variable torque select
OFF
5.13
BS, MC
33
Spinning motor select
0
6.09
B
34
Positive logic select
On
8.29
I
35
Start/Stop logic select
0
6.04
B, I
36
Analog output select
Fr
7.33
B
37
Switching frequency (kHz)
6
5.18
B
38
Auto tune
0
5.12
B
39
Rated frequency (Hz)
50.0
60.0
5.06
BS, MC
40
No. of poles
Auto
5.11
BS, MC
41
Serial mode
AnSI
11.24
BF, L1
42
Baud rate
4.8
11.25
BF
43
Serial address
1.1
11.23
BF
44
Software version
--
11.29
I
45
Fieldbus node address
0
15.03
46
Fieldbus baudrate
0
15.04
47
Fieldbus diagnostics
0
15.06
48
Voltage mode selector
3
5.14
BS,MC
49
Low frequency voltage boost
3.0
5.15
BF,MC
50
Motor thermistor select
OFF
8.40
LI
*51
Zero speed threshold
1.0
3.05
B
*52
Motor current threshold
0
4.01
B
*53
Motor current threshold
0
12.05
L3
*54
Brake release delay time
0
9.09
L3
Содержание COMMANDER SE
Страница 76: ...76 Commander SE Advanced User Guide Issue Number 4...
Страница 93: ...Commander SE Advanced User Guide 93 Issue Number 4...
Страница 98: ...98 Commander SE Advanced User Guide Issue Number 4...
Страница 142: ...142 Commander SE Advanced User Guide Issue Number 4 Figure 6 9 Input line reactor 4400 0241 All dimensions in mm...
Страница 144: ...144 Commander SE Advanced User Guide Issue Number 4 Figure 7 3 Commander SE Size 4 All dimensions in mm...