Commander SE Advanced User Guide
57
Issue Number: 4
See previous page for details.
This bit can be used to enable latches on the run forward, run reverse and run inputs to allow the drive to be controlled from
momentary inputs. See also parameters
6.30 ~ 6.34
and
6.04.
A user can use parameters
6.41
Control word mask,
6.42
Control Word and
6.43
Control word enable to start, stop, run
forward, run reverse etc. the drive via serial communications.
This parameter in conjunction with parameters
6.42
and
6.43
provides the means of controlling the drives Start/Stop functions
via serial communications.
The value set in parameter
6.41
is used to define and limit which functions can be controlled by the user i.e. Enable, Run
Forward, Run Reverse etc.
This value only needs to be set once to the appropriate value. This value is the binary code addition of the functionality
required.
This parameter is not saved when the drive is powered off
6.35 ~
6.38
Unused parameters
6.39
Digital input control bit 5 (Not Stop)
Ú
0 or 1
Ö
0
RW
Bit
6.40
Enable latching run inputs
Ú
0 or 1
Ö
0
RW
Bit
6.41
Control word mask
Ú
Ö
0
RW
Uni
Binary code
Function
1
Drive Enable
2
Run Forward
4
Jog
8
Run Reverse
16
Forward / Reverse
32
Run
64
Not Stop
Run Forward (
)
6.30
Run Reverse (
)
6.32
Run (
)
6.34
STOP (
)
6.39
Forward/Reverse
(
)
6.33
R.Fwd
R.Rev
RUN
LATCH
LATCH
LATCH
OR
OR
REV
S
S
S
R
R
R
NOTE
Содержание COMMANDER SE
Страница 76: ...76 Commander SE Advanced User Guide Issue Number 4...
Страница 93: ...Commander SE Advanced User Guide 93 Issue Number 4...
Страница 98: ...98 Commander SE Advanced User Guide Issue Number 4...
Страница 142: ...142 Commander SE Advanced User Guide Issue Number 4 Figure 6 9 Input line reactor 4400 0241 All dimensions in mm...
Страница 144: ...144 Commander SE Advanced User Guide Issue Number 4 Figure 7 3 Commander SE Size 4 All dimensions in mm...