Commander SE Advanced User Guide
31
Issue Number: 4
There are eight deceleration rates programmable for normal operation, plus one for jogging. The ramp rates are expressed
as a time for a change of 100Hz on the ramp output, therefore, with a programmed ramp time of 10 seconds the ramp output
will decelerate from 50Hz to 0Hz in 5 seconds.
Although the deceleration rate can be set to 0.0, there is a minimum ramp time within the software of 0.1s/100Hz
.
These bits are provided for control by logic input terminals for external ramp selection (see
2.10
&
2.20
).
2.29
Jog deceleration rate
Ú
0.1 ~ 3200.0
Ö
0.2
s/100 Hz
RW
Uni
2.30 ~
2.31
Unused parameters
2.32
Acceleration select bit 0 (LSB)
2.33
Acceleration select bit 1
2.34
Acceleration select bit 2 (MSB)
2.35
Deceleration select bit 0 (LSB)
2.36
Deceleration select bit 1
2.37
Deceleration select bit 2 (MSB)
Ú
0 or 1
Ö
0
RO
Bit
NOTE